ESAB PCC-10 Manual De Instrucciones página 22

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SeCTION 3
3.2
Control Connections
An 8-pin receptacle J1 is provided on the rear panel to supply the PCC-10 with 115 Vac control voltage for pump
motor contactor control. The PCC-10 must be supplied with this control voltage in order for the pump to operate.
Order Part No. 2062106; 8-Pin Female Plug and Part No. 182W61; Cable Clamp for plug to make a control cable us-
ing a two conductor cable. Solder the leads of this cable to Pins A and B of the plug and connect to control volt-
age device. Pump motor contactor control is supplied so as to not operate pump when cooling is not needed.
WArNINg
3.3
Coolant Connections
These connectors are located on the front of the unit and are marked "TO" and "FROM". Connect the hoses to
the PCC-10 accordingly. The torch hose ends should be fitted with one 0.63"-18 (16 mm) male left-hand Air/Water
hose and one 0.63"-18 (16 mm) female right-hand Air/Water hose connector.
With the torch and the PCC-10 connected, fill the reservoir with the specially formulated torch coolant (order
part no. 156F05). Do not use regular anti-freeze solutions, such as for an automobile, as the additives will harm
the pump and torch.
DO NOT INTerMITTeNTlY OPerATe The PuMP MOTOr AS ThIS WIll
CAuSe NeeDleSS WeAr TO The PuMP.
22
INSTAllATION
P/N 2062106; 8-Pin
Female Plug