Uso del control del navegador de internet
Contenido del correo enviado
• Cuando se han establecido los ajustes de E-mail se envía
el correo con el contenido mostrado abajo.
=== Panasonic projector report(CONFIGURE) ===
Projector Type
----- E-mail setup data -----
TEMPERATURE WARNING SETUP
MINIMUM TIME
INPUT AIR TEMPERATURE Over [ 45C / 113F ]
ERROR
LAMP1 RUNTIME
LAMP1 RUNTIME
LAMP2 RUNTIME
LAMP2 RUNTIME
INPUT AIR TEMPERATURE
PERIODIC REPORT
Sunday
[ ON ] Monday [ OFF ] Tuesday [ ON ] Wednesday [ OFF ]
Thursday [ ON ] Friday
00:00 [ ON ]
04:00 [ OFF ] 05:00 [ ON ]
08:00 [ ON ]
12:00 [ OFF ] 13:00 [ ON ]
16:00 [ ON ]
20:00 [ OFF ] 21:00 [ ON ]
----- check system -----
MAIN CPU BUS
FAN
OPTICS MODULE TEMPERATURE
INPUT AIR TEMPERATURE
AROUND LAMP TEMPERATURE
LAMP2 REMAIN TIME
LAMP1 REMAIN TIME
•
•
•
Página de ajuste del reloj
Haga clic en [Network set up], y luego en [Adjust clock] para visualizar la página de ajuste del reloj.
• Si el reloj se desajusta inmediatamente después de configurar la hora correcta, eso significa que
Nota
las pilas necesitan recambiarse. Póngase en contacto con el distribuidor donde compró el
proyector para cambiar la batería.
44
: D4000
at [ 60] minutes interval
[ ON ]
[ ON ]
at REMAIN [ 100] H
[ ON ]
at REMAIN [ 200] H
[ ON ]
at REMAIN [ 300] H
[ ON ]
at REMAIN [ 400] H
[ OFF ]
[ OFF ] Saturday [ ON ]
01:00 [ OFF ] 02:00 [ ON ]
03:00 [ OFF ]
06:00 [ OFF ] 07:00 [ ON ]
09:00 [ OFF ] 10:00 [ ON ]
11:00 [ OFF ]
14:00 [ OFF ] 15:00 [ ON ]
17:00 [ OFF ] 18:00 [ ON ]
19:00 [ OFF ]
22:00 [ OFF ] 23:00 [ ON ]
[ OK ]
[ OK ]
[ OK ]
[ OK ]
[ OK ]
[ OK ]
[ OK ]
• Cuando se ha producido un error se envía el
correo con el contenido mostrado abajo.
=== Panasonic projector report(ERROR) ===
Projector Type
: D4000
––––– check system –––––
MAIN CPU BUS
FAN
OPTICS MODULE TEMPERATURE
INPUT AIR TEMPERATURE
AROUND LAMP TEMPERATURE
LAMP2 REMAIN TIME
LAMP1 REMAIN TIME
LAMP2 STATUS
LAMP1 STATUS
SHUTTER
AIR FILTER
OPTICS MODULE TEMP.SENSOR
INPUT AIR TEMP.SENSOR
AROUND LAMP TEMP.SENSOR
BATTERY
AIRFLOW SENSOR
COLOR WHEEL
COVER OPEN
(Error code 00 10 00 00 00 00 00 00)
Input air temperature
Optics module temperature : 30 degC / 86 degF
Around lamp temperature
SET RUNTIME
30 H
POWER ON
33 times
LAMP1 ON
34 times
LAMP1 HIGH
5 H
LAMP2 ON
24 times
LAMP2 HIGH
4 H
LAMP1 REMAIN
1476 H
LAMP2 REMAIN
1484 H
----- Network configuration -----
IP address 192.168.0.8
MAC address 00:00:00:00:00:00
Thu Mar 02 14:11:02 2006
----- Memo -----
Selección de la zona horaria
Botón para actualizar la
configuración de la zona horaria
Campo de fecha nueva
Botón para actualizar las
configuraciones de hora y fecha
Campo de hora nueva
[
OK
]
[
OK
]
[
OK
]
[
OK
]
[
OK
]
[
OK
]
[
OK
]
[
OK
]
[
OK
]
[ FAILED ]
[
OK
]
[
OK
]
[
OK
]
[
OK
]
[
OK
]
[
OK
]
[
OK
]
[
OK
]
: 30 degC / 86 degF
: 37 degC / 98 degF