Care And Maintenance; Filter Replacement; Troubleshooting - AeraMax Professional Pro AM III Manual Del Usario

Ocultar thumbs Ver también para Pro AM III:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10

CARE AND MAINTENANCE

CLEANING:
• Clean external housing as necessary by wiping with a dry, soft cloth; for stains, use a warm, damp cloth.
• Do not use volatile fluids such as benzene, paint thinner, scouring powder or other cleaners that may damage the unit surface.
• Clean intake and exhaust vents by wiping with a dry, soft cloth.
FILTER REPLACEMENT INDICATORS:
The replacement filter indicators will signal when to replace the HEPA Filter and/or Carbon with Pre-Filter. The replacement period will vary depending on the hours of
use, air quality, and rate of air flow. However, under normal usage, most HEPA Filters need to be replaced every 2 years, and Carbon with Pre-Filter every 6 months.
When a filter needs to be replaced the following color will be shown on any one of the HEPA, CARBON, or ACCESSORY filter replacement indicators:
Red flashing = 90% filter wear (recommendation to order new filters)
Red steady = 100% filter wear (replace with new filters)
Do not wash and reuse any of the filters – they will not work effectively. Only use AeraMax ® PRO brand replacement filters as units will not function using
any other replacements.
FILTER REPLACEMENT PROCEDURE:
1
Unlock access panel: to unlock, insert
the key provided and rotate counter-
clockwise ¼ turn.

FILTER REPLACEMENT:

When installing a new filter the unit will automatically detect the filter type but the user will have to manually reset the filter replacement indicators. To reset any
of the filter replacement indicators use the following procedure:
1
Touch and hold the illuminated
indicator for three seconds until
a beep is heard and the indicator
is flashing green.
Note: If you do not complete step three within 10 seconds of completing step 1 then the indicator light will not be reset.

TROUBLESHOOTING

PROBLEM:
The air quality control system fails to start.
The unit makes a faint ticking sound.
The HEPA and/or Carbon Filter replacement indicator light
remain lit after replacing the filter(s).
2
Open front access panel by pressing
latches on both sides of unit. Allow
panel to open fully. Remove filter(s)
to be replaced.
2
Release finger from indicator.
POSSIBLE SOLUTION:
• Check to assure unit is connected to power supply.
• Make sure filters are genuine AeraMax
brands. IMPORTANT: Make sure filter detection area on genuine AeraMax
replacement filter aligns with window in filter frame.
• Review "Re-Installing Filters" section for further detail.
• Make sure front access panel is closed completely.
• Make sure power switch is on.
• This indicates that the "PlasmaTRUE™" bipolar ionizer is working.
• Repeat filter light reset instruction.
3
Remove any packaging wrap from the
new filters(s) and re-install the filters.
3
Touch and hold the indicator for three
seconds until a beep is heard and the
indicator light turns off.
®
PRO filters, as unit will not function with other
®
PRO
5

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Am3 pc

Tabla de contenido