Breakdown – detection and solutions
Pump does not start?
Have you checked...
If pump is connected to the mains?
If there is no current failure of the mains?
You might need to...
Check the mains
Low flow?
Have you checked...
If connectors of the suction part are perfectly airtight?
If the filter of the pump is not obstructed?
You might need to...
Repair connections and/or change the suction hose
Clean up the filter of the pump.
Pump does not prime ?
Have you checked...
Connections airtightness?
If pump positionning is in accordance with instructions (max 1m
above water level)?
If the filter of the pump is not obstructed
If the pump is full of water?
If power supply is correct?
You might need to...
Repair connections and/or change the suction hose.
Place
(recommended heights of suction and discharge).
Clean up the filter of the pump.
Fill the pump with water.
Abnormal noise?
Have you checked...
If the pump is correctly fixed on its support?
If the pump did not suck up dirt?
the
pump
in
accordance
with
its
performances