Descargar Imprimir esta página

peerless-AV ESA763PU Instalación Y Montaje página 13

Ocultar thumbs Ver también para ESA763PU:

Publicidad

Idiomas disponibles

Idiomas disponibles

• Do not lift more weight than you can handle. Use additional man power or mechanical lifting equipment to safely
handle placement of the display.
• Do not tighten screws with excessive force. Overtightening can cause damage to mount. Tighten M10 x 15mm
screws (E) to 40 in. • lb (4.52 N.M.) maximum torque.
Mounting Flat Panel Display
For Dedicated PLP Plate (not evaluated by UL):
5
Refer to PLP model instruction sheet for attachment
of dedicated PLP plate to display.
Install two M10 x 15mm screws (provided with
dedicated PLP plate) into top two holes of dedicated
PLP plate leaving 1/4" of exposed thread as shown
in fi gure 5.1.
DEDICATED
PLP PLATE
ADAPTER PLATE
fi g. 5.1
5-1
Insert two M10 x 15mm screws (E) into bottom holes of adapter plate as shown in fi gure 5.3 or 5.4. Tighten all
fasteners with 6mm allen wrench (H).
DEDICATED PLP PLATE
ADAPTER PLATE
fi g. 5.3
WARNING
1/4"
M10 X 15 MM
SCREW
A
ADAPTER PLATE
E
13 of 50
For Universal Adapter Bracket: Hook M10 x 15mm
screws into keyslots of wall arm adapter plate (A) as
shown fi gure 5.2.
DISPLAY NOT
SHOWN FOR
CLARITY
ADAPTER PLATE
fi g. 5.2
B
fi g. 5.4
ISSUED: 01-05-11 SHEET #: 061-9062-7 03-22-12
B
1/4"
M10 X 15 MM
SCREW
E
A

Publicidad

loading