Cleaning And Maintenance - HQ-Power VDPL800ST Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

• DMX512 Mode
Set DIP switch 10 to on to receive the DMX signal; refer to the table below the set the address.
DIP
1
1
The unit has 2 DMX channels. Refer to the table below for the setting.
Channel
1
2
• DMX512 Connection
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side to the
male 3-pin XLR input of the VDPL800ST. Multiple VDPL800STs can be linked through serial linking. The
linking cable should be a two-core screened cable with XLR input and output connectors.
• DMX512 Chain with Termination
• DMX Start Address Selection
All DMX-controlled devices need a digital start address so that the correct device responds to the signals. This
start address is the channel number from which the device starts to "listen" to the DMX controller. Enter the
correct number and read it from the display located on the base of the VDPL800ST.
You can use the same starting address for a whole group of devices or enter an individual one for every
device.
When all devices have the same address, all the VDPL800STs will "listen" to the control signal on one
particular channel. In other words: changing the settings of one channel will affect all devices simultaneously.
If you set different addresses, each device will "listen" to a separate channel number. Changing the settings of
one channel will only affect the device in question.
In the case of the 2-channel VDPL800ST, you will have to set the start address of the first VDPL800ST to 1,
the second VDPL800ST to 3 (1 + 2), the third to 5 (3 + 2) and so on.

6. Cleaning and Maintenance

1. All screws should be tightened and free of corrosion.
2. The housing, visible parts, mounting supports and the installation location (e.g. ceiling, suspension, trussing)
should not be deformed, modified or tampered with e.g. do not drill extra holes in mounting supports, do not
change the location of the connections.
3. Moving mechanic parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician maintain the device.
5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts except for the fuse.
8. Contact your dealer for spare parts if necessary.
VDPL800ST
2
3
4
2
4
8
Function
From
Strobe
Dimmer
A DMX terminator is recommended for installations where the DMX cable has to run a
long distance or is in an electrically noisy environment (e.g. discos). The terminator
prevents corruption of the digital control signal by electrical noise. The DMX terminator is
simply an XLR plug with a 120 resistor between pins 2 and 3, which is then plugged into
the XLR output socket of the last device in the chain.
Please see illustrations.
5
6
16
32
To
0
255
From slow to fast
0
255
From 0% to 100% output
5
7
8
9
64
128
256
Description
10
HQPOWER

Publicidad

Tabla de contenido
loading

Tabla de contenido