ROBLIN BALTIC Manual De Uso página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
• Clean the hood using a damp cloth
and a neutral liquid detergent.
Controls
Button Function
Turns the motor on/off at speed one.
A
With the motor turned off:
Saturation of the grease filters takes place after 100 hours of continuous
operation of the hood.
With the motor turned off:
Saturation of the activated charcoal filters takes place after 200 hours of
continuous operation of the hood.
Turns the motor on at speed two.
B
Press and hold the button for approximately 2 seconds, with all the loads
turned off (Motor+Lights), to turn the Activated Charcoal Filter alarm on. LED
(A) flashes twice to confirm.
To turn the alarm off, press the button again and hold for at least 2 seconds.
The relevant LED flashes once (A).
Turns the Motor on at speed three.
C
Press and hold the button for approximately 2 seconds, with all the loads
turned off (Motor+Lights), to reset the Filter saturation alarm. LED A flashes
three times.
Turns the motor on at INTENSIVE speed.
D
This speed is timed to run for 6 minutes. At the end of this time, the system
returns automatically to the speed that was set before. If it is activated with
the motor turned off, it will switch to OFF at the end of the time. To deactivate
it, press button D once more or press button A.
With all the loads turned off (Motor+Lights), press and hold D for approximately
2 seconds to enable the remote control. Button A flashes twice.
With all the loads turned off (Motor+Lights), press and hold D for approximately
2 seconds to disable the remote control. Button A flashes once.
Turns the lights on/off at maximum strength.
E
10
Lighting
• For replacement contact technical
Z
A
B
C
support ("To purchase contact tech-
nical support").
D
E
Led
Fixed.
Flashes once a
second.
Flashes once
every 0.5
seconds.
On.
Flashing.
On.
Flashing.
Flashing.
Flashing.
On.

Publicidad

Tabla de contenido
loading