Replacing The Ac Fuse; Replacing The Dc Fuse; Replacing The Dc Plug Fuse; Replacing The Light Pcb - Dometic CFX3 35 Instrucciones De Uso

Nevera por compresor
Ocultar thumbs Ver también para CFX3 35:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CFX3
7.22

Replacing the AC fuse

D
DANGER! Electrocution hazard
Disconnect the power supply and the connection cable before you
replace the device fuse.
➤ Disconnect the power supply to the device.
➤ Pull out the connection cable.
➤ Pry out the fuse insert (fig. 4 4, page 4) with a screwdriver.
➤ Replace the defective glass fuse with a new one of the same type and rating
(Fast Acting, 4 A, 250 V).
➤ Press the fuse insert back into the housing.
➤ Reconnect the power supply to the device.
7.23

Replacing the DC fuse

➤ Pry out the fuse cover (fig. 4 3, page 4) with a screwdriver.
➤ Reverse the fuse cover and use hook to remove the defective blade fuse.
➤ Push in a new fuse of the same type and rating.
– CFX3 35, CFX3 45, CFX3 55IM, CFX3 75DZ: 10 A
– CFX3 95DZ, CFX3 100: 15 A
➤ Re-fit the fuse cover.
7.24

Replacing the DC plug fuse

➤ Replace the defective fuse with a new fuse of the same type and rating.
– CFX3 35, CFX3 45, CFX3 55IM, CFX3 75DZ: 10 A
– CFX3 95DZ, CFX3 100: 15 A
➤ Proceed as shown (fig. p, page 15).
7.25

Replacing the light PCB

A
NOTICE! Damage hazard
The lamp can only be replaced by the manufacturer, service agent or
similarly qualified person to avoid hazard.
EN
Operation
31

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cfx3 45Cfx3 55imCfx3 75dzCfx3 95dzCfx3 100

Tabla de contenido