Battery Cable Connection (Electric Start Only); Operation; Know The Generator - Generac GP Serie El Manual Del Propietario

Ocultar thumbs Ver también para GP Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

BEND ONE TAB
OUTWARD
AFTER AXLE
PIN (G) IS
INSERTED
THROUGH
THE FRAME
1.2.2 BATTERY CABLE CONNECTION (ELECTRIC START
ONLY)
The unit has been deliberately shipped with the battery cables
disconnected.
To connect the battery, you will need two 8mm box wrenches to
connect the battery cables. (see Figure 17 for connection details):
1. Cut off cable ties securing battery cables and remove red
covers from battery terminals.
2. First, connect the red cable to the positive (+) battery terminal
with the bolt and nut supplied.
3. Make sure connections are secure and slide rubber boot over
the positive (+) battery terminal and connection hardware.
4. Connect the black cable to the negative (-) battery terminal
with the bolt and nut supplied and slide rubber boot over the
negative (-) battery terminal and connection hardware.
5. Make sure all connections are secure.
If the battery is unable to start the engine, charge it with the
12V charger included in the accessory box (see the "Charging a
Battery" section for details).
NOTE:

2.1 KNOW THE GENERATOR

this generator.
Compare the generator to Figures 4 through 6 to become
familiarized with the locations of various controls and adjustments.
Save this manual for future reference.
1. 120 Volt AC, 20 Amp, Duplex Receptacle
electrical power for the operation of 120 Volt AC, 20 Amp,
single-phase, 60 Hz electrical lighting, appliance, tool and
motor loads. CARB models are equipped with GFCI outlets.
2. 120/240 Volt AC, 30 Amp Locking Receptacle
electrical power for the operation of 120 and/or 240 Volt AC,
30 Amp, single-phase, 60 Hz, electrical lighting, appliance,
tool and motor loads.
3. Circuit Breakers (AC)
push-to-reset circuit breaker to protect the generator against
electrical overload.
4. Oil Drain
5. Air Filter
6. Choke Knob
7. Fuel Tank
8. Grounding Lug
ground here. See "Grounding the Generator" for details.
9. Run/Stop Switch
(pull start models).
9A. Start Switch
(electric start models only).
10. Muffler
11. Handle
loaded button to move handle.
12. Gas Cap
13. Fuel Gauge
14. Oil Fill
15. Recoil Starter
16. Fuel Shut Off
17. Battery Charger Input
to recharge the 12 volt DC storage battery provided with
the 12 Volt Adaptor Plug Charger which is included in the
Accessory Box. Located behind the battery charger input is
a 1.50 Amp in-line fuse which is inside the control panel to
protect the battery (electric start models only).
18. Battery
only).
19. Hourmeter