TECHNICAL DATA:
Voltage:
Frequency:
Rotation Frequency:
Thermal insulation on motor winding: F
MODEL
POWER
BOAP-1/2A
1/2 Hp
BOAP-3/4A
3/4 Hp
BOAP-1A
1 Hp
IMPORTANT NOTICE: To avoid risk of electrical shock or serious accident, if power cord gets damaged it should be repaired by the
manufacturer or by Truper
Power cord grips used in this product: Type"Y".
Assembly design in this product causes insulation to be affected by liquid spills or splashing
Before gaining access to terminals, all power circuits should be disconnected.
WARNING
USE
Agricultural applications in irrigation systems for mini-spraying or area spraying where the pressure requirements are larger due to the
height of the irrigation system and the minimum pressure required for the correct functioning of spraying or nebulization. In this type of
applications the use of centrifugal pumps is not recommended due to the low output pressure they handle.
Dish Sprayera
GENERAL SAFETY GUIDELINES
Read and understand all the instructions. Failure to follow all the following instructions may result in electric
WARNING
shock, fire and/or severe personal injury.
Carefully follow the following instructions to gain the best performance and a long duty cycle of the pump.
In the event of any problem please contact your Truper Authorized Service Center.
OPERATION CONDITIONS
These pumps have been designed to pump neutral and clear liquids with no suspended abrasive solids; under temperatures no higher than
104 ºF. Adequate for vegetable farms irrigation. Pumping non-aggressive liquids and to increase low pressure in the aqueduct network.
SET UP
The pumps shall be set up in a dry place, adequate ventilation and temperature not exceeding
104 ºF (Fig. A).
Set the pump in place on a solid flat surface using the adequate bolts to prevent from vibration. The
pump shall be set up in a horizontal position to allow the bearings to work properly. The suction
pipe diameter shall not be smaller than the suction inlet. If the suction height exceeds 157.4" use a
pipe with a large diameter. The output pipe diameter should be chosen to resist the flow speed and
required pressure in the force points. The suction pipe shall be set up with and upward angle facing
the suction inlet to prevent air pockets. (Fig. B). Double-check the suction pipe is completely
hermetic and to be submerged in water at least one meter to prevent air bubbles. It is advisable to
Power cord grips: Type Y
Build quality: Basic insulation.
120 V~
60 Hz
Insulation quality: Class I
Duty Cycle: 50 minutes work per 20 minutes idle. Maximum 6 hours per day.
3 450 RPM
IPX4
MAXIMUM
CURRENT
HEIGHT
5 A
131.2 ft
213.2 ft
8 A
229.6 ft
10 A
Authorized Service Center.
®
Overhead Irrigation System
install a check valve between the output and the speed
adjusting flow gate to prevent a dangerous water column
Fig. B
that exceeds 65.6 ft
MAXIMUM
MAXIMUM
SUCTION
MANOMETRIC
DEPTH
HEIGHT VALUE
26.2 ft
131.2 ft
26.2 ft
213.2 ft
26.2 ft
229.6 ft
INPUT
CONDUCTOR
DIAMETER
18 AWG
1 NPT
18 AWG
1 NPT
16 AWG
1 NPT
Irrigation Sprayer
Fig. A
104 ºF
maximum
2