Technical Data
Description
Inlet and Outlet Diameter
Minimum Inlet Pressure
Maximum Inlet Pressure
Conductors
Work Cycle
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
WARNING
Before gaining access to the terminals all power sources should be disconnected.
Power requirements
WARNING
The tool shall be connected to ground while in use to prevent electrical shock.
• Plug in the socket into a properly grounded power outlet as shown in example A.
Not all the power outlets are properly grounded. If in doubt, verify with a
qualified electrician.
• If the power outlet is a two-pole (two orifices), BY NO MEANS REMOVE OR
MODIFY THE GROUND CONDUCTOR OF THE PLUG. Use a temporary adapter
as shown in example B. Always connect the conductor ring as indicated.
CAUTION
When using an extension cable, verify the gauge is enough for
the power that your product needs. A lower gauge cable will cause voltage drop
in the line, resulting in power loss and overheating. The following table shows the
right size to use depending on cable's length and the ampere capability shown in
the tool's nameplate. When in doubt use the next higher gauge
Ampere
Capacity
from 0 A and up to 10 A
from 10 A and up to 13 A
from 13 A and up to 15 A
from 15 A and up to 20 A
WARNING
When using power tools outdoors, use a
"Outdoors Use". These extensions are especially designed for outdoors and reduce the risk of electric shock.
WARNING
All the cabling, electric connections and the ground connection in the system shall comply
with the OFFICIAL MEXICAN STANDARD NOM-001-SEDE, ELECTRIC INSTALLATIONS (USE) or with
the local codes and ordinances. Please employ a qualified electrician.
Code
Voltage
Frequency
Current
Speed
Power
50 minutes work per 20 minutes rest. Maximum 6 hours daily
Insulation
Number of
Conductors
3 (one grounded)
PRE-1/6
14635
Water Pressure Booster Pump
60 Hz
3 600 RPM
1/6 Hp
1/2 NPT
Maximum Height/Maximum Value
0,72 PSI
of total Manometer Height
145 PSI
Liquid Maximum Temperature
22 AWG x 3C with 221 °F insulation temperature
IP Grade
Class I
Power cord grips: Type "Y".
Tool Build quality: Basic Insulation
Thermal insulation on motor winding: Class F
Extension gauge
from 6 ft to 49 ft
18 AWG( * )
16 AWG
14 AWG
8 AWG
grounded extension cable labeled
127 V
1 A
IP44
Authorized Service Center.
CAUTION
|
higher than 49 ft
16 AWG
14 AWG
12 AWG
6 AWG
ENGLISH
29,5 ft
176 °F
A
B
3