Parameter
Room probe calibration (the parameter is expressed in eighths of degree)
/1
digital input configuration (0 = open contact, 1 = closed contact)
/6
door open alarm delay time (0 = excluded)
/7
Measurement input visualisation modes (0 = only cell sensor, 1= cell sensor and humidity sensor
/H
scanned every 5 seconds)
room probe reading
Pr
Humidity sensor read out
PrH
adjuster hysteresis (differential)
r0
min. operating setpoint selectable
r1
max. operating setpoint selectable
r2
Relative humidity adjustment hysteresis (differential)
r3
Dead zone relative humidity adjustment
r4
Relative humidity adjustable minimum setpoint
r5
Relative humidity adjustable maximum setpoint
r6
compressor activation delay from device start
C0
min. delay between compr. stop and subsequent start
C2
compressor start cycle time in the event of room probe alarm
C5
C5 % where compr. starts in the event of room probe alarm
C6
defrost interval (0= excluded)
d0
max. defrost duration (0 = the defrosting function will not star)
d3
defrosting display (0=actual cell temperature, 1=stopped cell temperature, 2=dEF label)
d6
defrost interval count: 0= actual hours; 1=hours comp. ON; 2= autodeterm.
dE
alarm hysteresis (differential)
A0
min. operating setpoint alarm (0= excluded)
A1
max. operating setpoint alarm (0= excluded)
A2
alarm exclusion from device start
A3
Buzzer alarm activation modality (0 = always; 1 = timed)
A4
Time limit for alarm buzzer acoustic notification (only if A4 = 1)
A5
temperature alarm exclusion time (only if A1 and/or A2 0)
A6
evaporator fan func. during regular operation (0=OFF; 1=ON; 2=parallel with compressor)
F3
Configuration parameters printing enable (0 = disabled)
P0
Sampling time (see also parameter P6)
P1
Selection of temperature probe to be printed (0 = none, 1=chamber probe, 2 = chamber and
P2
evaporator probe)
Payslip heading selection (0 =excluded, 1 = BTV Display Case, 2 = BTS Display Case)
P3
Equipment identification number printing enable (0 = no, 1= yes)
P4
Selection of language for payslip heading (1=Italian, 2=English, 3=French, 4=Spanish, 5=German)
P5
Selection of unit of measure for sampling time (1 = minutes, 2 =hours)
P6
Instrument address (date detected in printing phase if P4 = 1)
L1
Serial port management (o = not utilised, 1 = print)
L2
Baud Rate data transmiss. (1=2400, 2=4800, 3=9600, 4=18200)
L3
Transmission control mode (0 = no parity, 1 = odd, 2 = even)
L4
Description
MEASUREMENT INPUTS
COMPRESSOR ADJUSTMENT
COMPRESSOR PROTECTION
EVAPORATOR FAN ADJUSTMENT
COMMUNICATIONS MANAGEMENT
USER PARAMETER CONFIGURATION - PROBE READING
Push the up and down buttons simultaneously and hold down for more than 3
seconds.
The label [Loc] is visualised.
Utilise the up and down buttons to scroll the sensor probe readings and the
user parameters.
DEFROST
ALARMS
PRINT
14
"UNITS +14°C/+16°C"
Default
min
MAX
8°C
-40
+99
0
0
120 sec
0
240
0
0
- °C
-
-%
-
+3°C
1
+14°C
-40
+16°C
r1
+99
5%
0%
15%
-20%
0%
10%
40%
20%
80%
60%
20%
80%
1 min
0
240
2 min
0
240
10 min
1
240
40 %
0
100
0 hours
0
5 min
0
1
0
0
0
+2 °C
1
-3 °C
-40
+15 °C
0
+99
120 min
0
240
1
0
1 min
0
240
60 min
0
240
1
0
1
0
60 min
1
2
0
1
0
1
0
1
-1
1
1
1
0
255
1
0
3
1
0
0
1
1
-
-
15
r2
99
99
2
2
15
0
1
2
1
60
2
2
1
5
2
1
4
2