Flue Gas Exhaust - Palazzetti ECOFIRE MARIANNE OLLARE Manual De Instalación Y Mantenimiento

Estufa de pellets
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

"S
"
EALED
MODE INSTALLATION
These pellet stoves allow the following possible
installation alternatives:
• ducted combustion air using a coaxial pipe to
consequently no fresh air vent is needed in the
room (Fig. 5.5 A, B=Air intake C, D=Flue gas
outlet);
• connect the stove combustion air intake to the
fresh air opening using a special pipe (Fig. 5.6).
• As an additional safety measure, there is a
connect the condensate drain pipe, if an unlikely
event may require such measure (Fig. 5.12).

5.5 FLUE GAS EXHAUST

The stove operates with negative pressure in the
gas discharge must be airtight.
The stove must be connected to its own
ensuring adequate atmospheric dispersion of the
combustion byproducts.
conditions and bear the CE mark.
An initial vertical section measuring a minimum of
exhaust.
There should be at least three changes in direction
at the rear of the stove, using 45 or 90° angle
connectors or 'T' connectors (Fig. 5.7).
Use always a 'T' connector with inspection cap on
The maximum length of horizontal sections is 2-3
m with an upwards slope of 3-5% (Fig. 5.7).
connected to:
• a chimney used by other heat generators (boilers,
• air exhaust systems (range hoods, vents, etc.....)
even if these are ducted.
Shut-off or draught valves must not be used.
Combustion byproducts must be discharged
through the roof.
24
INSTALLATION
fig. 5.5
B
fig. 5.6
B
B
fig. 5.7

Publicidad

Tabla de contenido
loading

Tabla de contenido