Maintenance And Care - Schumacher Electric SC1309 Manual Del Usuario

Ocultar thumbs Ver también para SC1309:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

AUTOMATIC CHARGING MODE
When an Automatic Charge is performed,
the charger switches to the maintain mode
automatically after the battery is charged.
ABORTED CHARGE
If charging cannot be completed normally,
charging will abort. When charging aborts,
the charger's output is shut off, and the
display will show "bad bat" and an error
code. To reset after an aborted charge,
unplug the charger from the AC outlet, wait
a few moments and plug it back in.
DESULFATION MODE
The display will show "SUL" when a sulfated
battery is detected, and the charger will go
into desulfation mode. If the desulfation is
not successful after 10 hours, the charger
will go into abort mode and the display will
show "bAd / bAt / F02".
COMPLETION OF CHARGE
Charge completion is indicated by the
CHARGED/MAINTAINING (green) LED.
When pulsing, the charger has switched to
the maintain mode of operation.
MAINTAIN MODE
(FLOAT MODE MONITORING)
When the CHARGED/MAINTAINING
(green) LED is pulsing, the charger has
started maintain mode. In this mode, the
BATTERY CHARGING TIMES
CCA = Cold Cranking Amps
SMALL BATTERIES
Motorcycle, garden tractor, etc.
CARS AND
TRUCKS
MARINE/DEEP-CYCLE
Times are based on a 50% discharged battery and may change, depending on
age and condition of battery.

12. MAINTENANCE AND CARE

A minimal amount of care can keep your
battery charger working properly for years.
• Clean the clamps each time you are
finished charging. Wipe off any battery
fluid that may have come in contact with
the clamps to prevent corrosion.
• Occasionally cleaning the case of the
charger with a soft cloth will keep the
finish shiny and help prevent corrosion.
RC = Reserve Capacity
BATTERY SIZE/RATING
200-315 CCA
315-550 CCA
550-1000 CCA
charger keeps the battery fully charged
by delivering a small current when
necessary. If the charger has to provide
its maximum maintain current for a
continuous 12 hour period, it will go into
abort mode (see Aborted Charge section).
This is usually caused by a drain on the
battery or the battery could be bad. Make
sure there are no loads on the battery. If
there are, remove them. If there are none,
have the battery checked or replaced.
MAINTAINING A BATTERY
The SC1309 charges and maintains
6 and 12 volt batteries, keeping them at
full charge.
NOTE: The maintain mode technology
allows you to safely charge and maintain
a healthy battery for extended periods of
time. However, problems with the battery,
electrical problems in the vehicle, improper
connections or other unanticipated
conditions could cause excessive current
draws. As such, occasionally monitoring your
battery and the charging process is required.
FAN OPERATION
It is normal for the fan to be on all the
time. Keep the area near the charger
clear of obstructions to allow the fan to
operate efficiently.
Ah = Amp Hour
CHARGE RATE/TIME
6-12 Ah
12-32 Ah
40-60 RC
60-85 RC
85-190 RC
80 RC
140 RC
160 RC
180 RC
• Coil the input and output cords neatly
when storing the charger. This will help
prevent accidental damage to the cords
and charger.
• Store the charger unplugged from the AC
power outlet in an upright position.
• Store inside, in a cool, dry place. Do not
store the clamps on the handle, clipped
together, on or around metal, or clipped
to the cables.
• 9 •
6A<>2A
1½-2½ h
2½-7 h
7½-9½ h
9½-12 h
12-23 h
12 h
18 h
20 h
22 h