3.3 Magnetic key

The magnetic key is used to select all the functions of the electronic urinal, by holding it in front
of the right-hand control unit sensor.

3.4 Factory settings

The electronic urinal has the following factory settings:
Flushing programme
Detection time/dwell time:
Flushing programmes are set as follows:
Flushing
pro-
gramme
0.5 litres (P1)
Standard (P2)
Vario (P3)
*
50% of full flush, at least 1.5 l (5 sec)
The flush volume depends on the pressure and cross-sectional build of the pipe.
Information for 3.5 bar flow pressure.

3.5 Flushing programmes

Full flush approx. 2.1 litres at 3.5 bar flow pressure
Reduced flush approx. 1.5 litres at 3.5 bar flow pressure
The flush volume depends on the pressure and cross-sectional build of the pipe.
0,5 litres (P1)
The 0.5-litre flushing programme is set by default and is triggered after each use (Flush approx.
0.5 litres at 3.5 bar flow pressure).
Standard (P2)
The Standard flushing programme is suitable for locations where a full flush is required after
each use.
Vario (P3)
The Vario flushing programme adjusts the flush volume to the frequency of use. It has 2 available
operating modes. The Vario flushing programme is suitable for hotels, restaurants, exhibition
halls, airports and other public facilities.
Operating mode 1
While the urinal is used fewer than 3 times every 30 minutes, the full flush is triggered after each
use.
Operating mode 2
If the urinal is used 3 or more times every 30 minutes, the third use will trigger a reduced flush.
If the urinal is not used for 120 minutes, then a full flush will be triggered after the next time it is
used, and operating mode 1 will be reactivated.

3.6 Service programmes

5-minute flush stop (S1)
In order to manually clean the electronic urinal, the flushing programme is deactivated for 5 min-
utes. Then a full flush occurs and the chosen flushing programme is reactivated.
18
Full flush
Volume
Duration
0.5 l
2 sec
2.1 l
7 sec
2.1 l
7 sec
Factory setting
0.5 litres (P1)
9 seconds
Setting
range
-
5-20 sec
5-20 sec
Reduced flush*
Volume
Duration
-
-
1.5 l
5 sec
-
-

Publicidad

Tabla de contenido
loading

Tabla de contenido