AVENTICS | ST6 | R412024085-BAL-001-AC | English
General safety instructions
W Observe the regulations for accident prevention and
environmental protection in the country where the product
is used and at the workplace.
W Do not modify or convert the device.
W Only use the device within the performance range provided
in the technical data.
W The warranty will not apply if the product is incorrectly
assembled.
W Do not place any improper mechanical loads on the product
under any circumstances.
Safety instructions related to the product
and technology
On installation
W Make sure the relevant system component is not under
pressure or voltage before assembling the product or when
connecting and disconnecting plugs.
During operation
W Only commission the sensor after it has been completely
assembled, as well as correctly connected and tested.
W Observe the operating conditions and data printed on the
relevant sensor or stated on its rating plate.
W Do not disconnect plugs or lines when the sensor is under
voltage.
ATEX – information on explosion protection
ST6-ATEX sensors are certified and labeled according to the
enclosed declaration of conformity.
They can be used
W with gases, mists, or vapors in zone 2
W with flammable dust particles in zone 22
Explanations concerning identification
Year of manufacture of the sensor: The first two digits
in the 5-digit date code on the rating plate indicate the year
and the last two digits indicate the week.
II 3G Ex nA IIC T4 Gc X
II 3D Ex tc IIIC T135°C Dc X
Due to the small size of the sensor, the ATEX identification
is located on a cable flag.
Danger of an ignition source due to impermissible operating
conditions, connections, and parameters!
Operating the sensor under impermissible operating conditions
can result in an explosion.
O
Observe the permissible operating conditions, in particular
the ambient temperature and the mechanical protection
for the device.
O
The ST6-ATEX sensor is only intended for complete
installation in suitable T-slots.
O
Note the limited temperature range for ATEX conditions.
O
Do not disconnect the plug connectors and the connecting
cable from the sensor if it is under voltage.
O
Only use approved M8 and M12 connecting cables from
the AVENTICS GmbH product offering.
O
Observe the relevant Ex guidelines for installation,
maintenance, and repair, especially EN 60079-14.
The device will lose its Ex approval if these instructions are not
complied with!
3

Delivery Contents

W 1x ST6-ATEX sensor
W 1 set of operating instructions (R412024085)
Variants with M8 and M12 plugs:
W Cable with plug and removal protection clip
4

About This Product

The ST6-ATEX sensor is used to detect magnetic fields in explosive
areas.
Product identification
O
Observe the product information on the product and
packaging.
5

Assembly and Commissioning

BN
BU
BK
Sensor porting configuration
O
Observe the Ex guidelines as per EN 60079-14.
O
The installation of electrical devices must be carried out
in accordance with applicable national regulations and
performed or supervised by an electrical specialist
(in compliance with TRBS 1203 or equivalent).
O
Compare the information on the device with the information
in the operating instructions before installation.
WARNING
1
+
3
R
4
L
4