Maintenance
ATTENTION! Before performing any
maintenance operation, isolate the
hood from the electrical supply by
switching off at the connector and
removing the connector fuse.
Or if the appliance has been connected
through a plug and socket, then the plug
must be removed from the socket.
The cooker hood should be cleaned
regularly (at least with the same frequency
with which you carry out maintenance
of the fat fi lters) internally and externally.
Clean using the cloth dampened with
neutral liquid detergent. Do not use
abrasive products.
DO NOT USE ALCOHOL!
WARNING: Failure to carry out the
basic cleaning recommendations of
the cooker hood and replacement
of the filters may cause fire risks.
Therefore, we recommend observing
these instructions.
The manufacturer declines all responsibility
for any damage to the motor or any
fi re damage linked to inappropriate
maintenance or failure to observe the above
safety recommendations.
Grease fi lter
Fig. 26-31
This must be cleaned once a month (or
when the fi lter saturation indication system
– if envisaged on the model in possession
– indicates this necessity) using non
aggressive detergents, either by hand or in
the dishwasher, which must be set to a low
temperature and a short cycle.
When washed in a dishwasher, the grease
fi lter may discolour slightly, but this does
not affect its fi ltering capacity.
Charcoal fi lter (fi lter version only)
Fig. 28
The charcoal fi lter can be washed once
every two months (or when the fi lter
saturation indication system – if envisaged
on the model in possession – indicates this
necessity) using hot water and a suitable
detergent, or in a dishwasher at 65°C (if
the dishwasher is used, select the full cycle
function and leave dishes out).
Eliminate excess water without damaging
the fi lter, then remove the mattress located
inside the plastic frame and put it in the
oven for 10 minutes at 100° C to dry
completely. Replace the mattress every 3
years and when the cloth is damaged.
Replacing lamps
Fig. 32
Disconnect the hood from the electricity.
Warning! Prior to touching the light
bulbs ensure they are cooled down.
Replace with a new 12 Volt, 20 Watt
(Maximum) halogen light made for a G-4
base SUITABLE FOR USE IN OPEN
LUMINAIRES. Follow package directions
and do not touch new light with bare
hands.