Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

JOB STORAGE AND RECALL
The current settings are automatically saved and will load next time the machine is used.
In addition to the current settings, it is possible to save and recall so-called «JOB» configurations.
There are 100 JOBS per welding process, the memorisation includes:
- The main parameter,
- The secondary parameter,
- Subprocesses and button modes.

JOB MODE

This mode allows you to create, save, recall and delete JOBs.
QUICK LOAD – Recall of the JOBs using the trigger when not welding.
The Quick Load is a JOB recall mode (20 max) excluding welding and possible only in MIG-MAG and TIG processes.
From a Quickload list of previously created JOBs, JOBs are recalled by pulling the trigger briefly. All trigger modes (2T/4T) and welding modes (SPOT/
STD/PLS) are supported.
OPTIONAL TORCH
• Push-Pull Torch (4m : ref. 046283 / 6m : ref. 048713) :
The Push-Pull torch is mounted on the connector (FIG 1 - 9). This type of torch allows the use of AlSi wire even in Ø 0.8 mm with a 4 or 6 m long
torch. This torch can be used in all modes.
The detection of the Push-Pull torch is done by simply pulling the trigger.
If a potentiometer Push-Pull lamp is used, the setting on the interface is used to set the maximum value of the adjustment range.
The potentiometer then allows to vary between 50% and 100% of this value.
Connection diagram for Push Pull torch
with potentiometer (10 KΩ)
1 - Choice of setting (speed or arc height)
2 - Orange LED (arc height)
3 - Green LED (speed)
4 - Increment (speed or arc according to button 2)
5 - Decrement (speed or arc according to button 2)
PRODUCT SETTINGS
INFORMATION
This menu provides access to version numbers of the boards and software.
46
NEOPULSE 220 C / 220 C XL
1
4
8
+4
+Pot 10
3
R
7
-Pot 3
-5
10
+
-
1
8
M
1
2
3
5
4
EN
2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Neopulse 220 c xl

Tabla de contenido