Symbol Definitions; Important Safeguards - DeVilbiss Healthcare SleepCube DV55 Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

SYMBOL DEFINITIONS

Class II electrical protection-
double insulated
Data port input/output
Next item on LCD display
Previous item on LCD display
Increase value on LCD
display
Decrease value on LCD
display
The device contains electrical and/or electronic equipment that must be recycled per EU Directive 2012/19/EU -
Waste Electrical and Electronic Equipment (WEEE)

IMPORTANT SAFEGUARDS

READ ALL INSTRUCTIONS BEFORE USING
THIS DEVICE.
SAVE THESE INSTRUCTIONS.
DANGER
Electric Shock Hazard – Do not use while bathing.
Electric Shock Hazard – Do not immerse this device into water or any other liquid.
Electric Shock Hazard – Do not attempt to open or remove the cabinet. There are no user-serviceable internal
components. If service is required, return the product to your home care provider. Opening or tampering with the
product will void the warranty.
WARNINGS
WARNING - APPLIED PARTS THAT MAY EXCEED 41 ˚C.
The following surface temperatures may exceed 41 ˚C under certain conditions:
External surface of the CPAP .............................. 42.7 ˚C
Patient Tubing Connector .................................... 43.9 ˚C
LCD Display ......................................................... 42.0 ˚C
On/Off & Delay Button ......................................... 41.8 ˚C
Humidifier Heater Plate ....................................... 60.6 ˚C
Serial Communication Port .................................. 42.7 ˚C
The DeVilbiss SleepCube should be used only with masks recommended by DeVilbiss, your physician or respiratory
therapist.
To avoid rebreathing of exhaled air, do not use a CPAP mask unless the device is turned on and providing a supply
of air. Venting in the mask should never be blocked. When the device is turned on and providing a fresh supply of
air, exhaled air is flushed out of the mask vent. However, when the device is not operating, exhaled air may be
rebreathed. Rebreathing of exhaled air for longer than several minutes can, in some circumstances, lead to
suffocation. This warning applies to most CPAP devices.
The DeVilbiss SleepCube is not a life support device and may stop operating with certain device faults or a power
failure. It is intended to be used on spontaneously breathing individuals weighing 66 lbs/30 Kg or greater.
To avoid electric shock, always unplug power cord from wall outlet power source when performing cleaning.
Use only accessories recommended by DeVilbiss.
Always remove the water chamber from the optional humidifier cradle before filling.
If water has spilled onto the humidifier cradle or it has been submerged into water, unplug power cord from power
source immediately. Allow device to dry completely before use.
EN - 4
Locked
Unlocked
IPX1 Drip-proof, vertical
DC input: 12 VDC, center pin
positive
Attention, consult
accompanying documents
Type BF equipment-applied
part
Standby-turns blower on/off
Heat
100-240 VAC input 50/60 Hz
Delay-starts the delay cycle
Manufacturer
SE-DV56-1

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Sleepcube dv56 serieSleepcube dv5hh

Tabla de contenido