LEGRAND WattStopper RS-150U Instrucciones De Instalación
LEGRAND WattStopper RS-150U Instrucciones De Instalación

LEGRAND WattStopper RS-150U Instrucciones De Instalación

Publicidad

Idiomas disponibles

Idiomas disponibles

Please read all instructions before installing
PIR Application-Specifi c
SPECIFICATIONS
Voltage ............................................................... 120VAC, 60Hz
Load (Single Pole Circuit)
Incandescent or fl uorescent light...................... 0-600 Watt
Fan motor .................................................................. 1/6 hp
Time Delay................................................................ 5 minutes
Environment ..................................Residential Indoor use only
Operating Temperature ............... 32° to 131°F (0° to 55°C)
Humidity ...................................... 95% RH, non-condensing
Tools Needed
Insulated Screwdriver
Wire Strippers
DESCRIPTION AND OPERATION
The RS-150U Application-Specifi c Wall Switch Occupancy Sensor is designed
to replace a residential light switch. It is ideal for laundry rooms, utility rooms,
storage areas, closets and any other indoor area in a residential building where
occupancy sensor-based automatic ON/OFF controls are desirable. The sensor
requires no adjustments to operate successfully in those particular applications
for which it was designed.
Lighted Switch
To help you locate the RS-150U in a dark room, an amber LED illuminates the
ON/OFF button while the controlled light (load) is OFF. When the load is ON, the
LED is OFF.
Push Button
The push button can be used to manually turn ON and OFF the load. To turn the
load OFF, tap fi rmly on the push button once. The lighted switch will turn ON
and the load will turn OFF. If the load is turned OFF manually, Automatic-ON is
reenabled when no motion is detected for 5 minutes.
Time Delay
The RS-150U has a fi xed time delay of 5 minutes. Lights will remain ON for 5
minutes after the last motion detection.
Coverage Area
The RS-150U has a maximum range of 180
degrees and a coverage area of 600 sq. feet (56
sq, meters). The sensor must have a clear and
unobstructed view of the coverage area. Objects
blocking the sensor's lens may prevent detection
thereby causing the light to turn OFF even though
someone is in the area.
Windows, glass doors, and other transparent barriers will
obstruct the sensor's view and prevent detection.
Call 888.817.0571 for Technical Support
RS-150U
Wall Switch
Occupancy Sensor
with Manual ON/OFF
Lens
Lighted Switch
ON/OFF Button
Santa Clara, CA 95050
12'
(3.7m)
Fig. 1: Sensor Coverage Area
25'
(7.6m)

Publicidad

Tabla de contenido
loading

Resumen de contenidos para LEGRAND WattStopper RS-150U

  • Página 1 Please read all instructions before installing RS-150U PIR Application-Specifi c Wall Switch Occupancy Sensor with Manual ON/OFF Lens Lighted Switch ON/OFF Button SPECIFICATIONS Voltage ............... 120VAC, 60Hz Load (Single Pole Circuit) Incandescent or fl uorescent light...... 0-600 Watt Fan motor ..............1/6 hp Time Delay..............
  • Página 2 INSTALLATION & WIRING WARNING Disconnect power to the wall switch box by turning OFF the circuit breaker or removing the fuse for the circuit before installing the RS-150U, replacing lamps, or doing any electrical work. 1. Prepare the switch box. HOT (power from After the power is turned OFF at the circuit circuit box)
  • Página 3: Test Mode

    WARRANTY INFORMATION Watt Stopper/Legrand warranties its products to be free of defects in materials and workmanship for a period of fi ve (5) years. There are no obligations or liabilities on the part of Watt Stopper/Legrand for consequential damages arising out of, or in connection with, the use or performance of this product or other indirect damages with respect to loss of property, revenue or profi...
  • Página 4: Especificaciones

    Por favor leer todas las instrucciones antes de realizar la instalación RS-150U Sensor de Ocupación Infrarrojo-pasivo de pared sin ajustes con control manual de ENCENDIDO/ APAGADO Lente Botón iluminado de ENCENDIDO/APAGADO ESPECIFICACIONES Voltaje ................120VAC, 60Hz Carga (Circuito unipolar) Lámparas incandescentes o fl uorescentes ..... 0-600 Watts Un motor ..................
  • Página 5: Instalacion Y Cableado

    INSTALACION Y CABLEADO ADVERTENICA Desconecte la corriente que alimenta la caja de conexiones apagando el disyuntor (breaker) o removiendo el fusible para el circuito correspondiente antes de instalar el RS-150U, reemplazar luces, o realizar cualquier trabajo eléctrico. LINEA/FASE (proveniente de la 1.
  • Página 6: Modo De Prueba

    (5) años. No existen obligaciones o responsabilidades por parte de Watt Stopper / Legrand por daños ocasionados por o en conexión con el uso o desempeño de este producto u otros daños indirectos en materia de pérdida de propiedad, ventas o ganancias, o...

Tabla de contenido