Menu 9. Stove State; User Mode; Stove Or Insert Ignition; Stove Or Insert In Operation - Bio Bronpi NEVA Instrucciones De Instalación, Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

9.4.10

MENU 9. STOVE STATE

It shows up the current state of the stove or insert and provides information about the devices connected. Therefore, the user can get a
technical information. The next screens are seen automatically (see drawing D74, D75, D76).
29ºC
AMBIENT
1.0b
3.7
SPEED
STATE 5
OPERATIONAL
MENU
D74
9.5

USER MODE

Below is a description of the control normal operation according to the available
functions.
Before the ignition of the stove or insert, the control shows the following screen (see
drawing D77): It is showed up the "off" state, the room temperature, the established
working power and the current hour.
9.5.1

STOVE OR INSERT IGNITION

In order to ignite the stove, press button no. 3 during a few seconds. The control will
show the ignition state as follows (see drawing D78):
The maximum length of the ignition phase is 20 minutes. After this time, if there is no
visible flame, the stove will automatically go into the alarm state and the control will show
the message "Ignition Failure."
9.5.2

STOVE OR INSERT IN OPERATION

The hot air fan will start when the smoke temperature reaches a minimum. Auxiliary fans
(in case of models of channelling stoves Alicia Extra, Clara Extra, Cleo Extra and Olivia
Extra) will start only if enabled.
In this moment, the stove or insert is correctly burning. After this, our stove will be
working normally (see drawing D79).
The control shows the ambient temperature in the room.
9.5.3

CHANGE OF THE SET-POINT ROOM TEMPERATURE

In order to modify the setting room temperature, please press button 4 and then buttons
1 and 2 to increase or decrease it respectively (see drawing D80).
9.5.4

ROOM TEMPERATURE REACHES TEMPERATURE FIXED BY THE USER

When the ambient temperature (of the room) reaches the value set by the user or the
smoke temperature reaches a too high value, the stove or insert will automatically
operate at one lower power, it means that modulates in power. See drawing D81.
Remember that if it is activated "stand-by mode", when the ambient temperature
reaches the value set by the user plus a differential (2ºC) the stove or insert will be
automatically turned off and will be on hold until the ambient temperature falls to
the set temperature minus a differential (2ºC). After that, the stove or insert restarts
automatically.
9.5.5

BURNER CLEANING

While the stove or insert is working normally, some automatic cleanings of the burner
take place in several minutes intervals. This process consists of cleaning the rest of
pellet remaining in the burner in order to guarantee a proper working of the stove or
insert (see drawing D82) and it takes several seconds.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
99ºC
SMOKE
2600
SPEED EXTR.
STATE 6
OPERATIONAL
MENU
D75
41
10"
TIME-OUT
80"
TIME CLEANING
194 V RETE
00 A 19.7 V
FAN
CHARACTERISTICS
MENU
D76
14:24
14:24
21º C
P-2
21º C
IGNITION
OFF
MENU
MENU
D77
15:18
21º C
SET TEMPER
21º C
P-3
WORKING
ROOM
MENU
MENU
D79
16:40
16:40
27º C
P-2
22º C
WORKING
BURNER
MODULATE
CLEANING
MENU
MENU
D81
RADIOFREQUENCY SERIES
P-2
D78
D80
P-2
D82

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido