Battery Recharger; Batteries Recharging; Batteries Disposal; Connection Batteries' Connector And Switching On Of The Machine - ADIATEK sapphire 65 Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

GB

BATTERY RECHARGER

Make sure that the battery recharger is suitable
for the installed batteries both for their capaci-
ties and type (lead/acid or GEL and equivalent).
In the plastic bag containing the use and mainte-
nance you will find the coupling connector for the
recharger. It must be assembled onto the cables of
your recharger, following the instructions given by
the manufacturer.
ATTENTION:
This operation must be carried out by qualified staff.
A wrong or faulty cable connection can cause seri-
ous damages to persons or things.

BATTERIES RECHARGING

1. Plug the connector (3) of the battery recharger
into the battery connector (1).
2. Proceed for the recharging.
ATTENTION:
Never charge a GEL battery with a non suitable
recharger. Strictly follow the instructions sup-
plied by the batteries and recharger manufactur-
er.
In order not to cause permanent damages to the
batteries, it is necessary to avoid their complete dis-
charge, providing for the recharging within a few
minutes after that the batteries discharge signal
starts blinking.
NOTE: Never leave the batteries completely dis-
charged even if the machine is not used. In case of
traditional batteries, please check the electrolyte
level every 20 recharging cycles and eventually top
them up with distilled water. Never leave the batter-
ies discharged for more than two weeks.
ATTENTION:
For the recharge of the batteries it is necessary to
follow strictly all the indications given by the manu-
facturer/distributor. All the installation and mainte-
nance operations must be carried out by qualified
staff. Danger of gas exhalations and emission of
corrosive liquids. Fire danger: do not approach
with free flames.

BATTERIES DISPOSAL

It is compulsory to hand over exhausted batteries,
classified as dangerous waste, to an authorized insti-
tution according to the current laws.
CONNECTION
BATTERIES'
CONNECTOR
SWITCHING ON OF THE MACHINE
Once that the battery recharging has been complet-
ed:
1. Disconnect the connector of the battery re-
charger from the battery connector (1).
2. Connect then the battery connector (1) to the
machine connector (2).
To start any function of the machine, it is necessary
to rotate clockwise the key switch. Rotating it coun-
terclockwise any function will be switched off (see
pos. 24 in "LEGEND PANEL OF CONTROLS").

BATTERIES CHARGE LEVEL INDICATOR

To start any function of the machine, it is necessary
to rotate clockwise the key switch (24). Rotating it
counterclockwise any function will be switched off.
WHEN THE MACHINE IS SWITCHED ON, ON THE DIS-
PLAY (1) APPEAR IN ORDER THE FOLLOWING INFOR-
MATION:
1. model of the machine (for example AdL).
2. the indication of the setting of the battery check
card which can be:
GE 36 (check card set for GEL batteries).
or
Pb 36 (check card set for lead batteries).
22
AND
3. the version of software of the check card in-
stalled on the machine (for example 4-6).
4. The batteries charge level indicator is digital and
remains fixed on the display. The battery charge level
starts from -100-, which indicates the 100% of the
total charge and decreases from 10 to 10. When the
charge level reaches the value -20-, the display
starts blinking, so you are about the end of working.
ATTENTION:
After a few seconds of the indication -10- blinking,
automatically the brushes function is stopped, while
the suction continues to work. On visualization of
the four blinking lines, also the suction will stop au-
tomatically. The traction instead will function, so to
transfer the machine to the suitable place for tank
draining and battery recharging.

SETTING OF THE BATTERY CHECK CARD

The setting of the battery check card can be:
GE 36 (check card set for GEL batteries).
or
Pb 36 (check card set for lead batteries).
The machine, if not specified otherwise, is supplied
with the battery check card set for lead batteries. To
modify this setting, it is necessary to:
1. Switch off and on the machine.
2. Immediately after having switched on, when on
the display (1) the writing Pb36 appears, press simul-
taneously the push buttons (3) and (6) up to the
blinking of the writing.