Maintenance schedule
Daily check
Bar lubrication
Before each use
Chain tension
Before each use and frequently
Chain sharpness
Before each use, visual check
For damaged parts
Before each use
For loose fasteners
Before each use
Chain brake function
Before each useInspect and clean
Guide Bar
Before each use
Complete saw
After each use
Chain Brake
Every 5 hours of operation
Replacement parts (Bar and chain)
Manufacturer
Chain
Guide Bar
Chain must be tted with bar from the same manufacturer accor-
ding to above combinations.
Exploded view
If needed, an exploded view of the tool can be ordered. Please state
the Article No. as well as the machine type printed on the label
and order the drawing at your local service agents or directly at:
Techtronic Industries GmbH, Max-Eyth-Straße 10, 71364 Winnen-
den, Germany.
BATTERIES
Battery packs which have not been used for some time should be
recharged before use.
Temperatures in excess of 50°C (122°F) reduce the performance of
the battery pack. Avoid extended exposure to heat or sunshine (risk
of overheating).
The contacts of chargers and battery packs must be kept clean.
For an optimum life-time, the battery packs have to be fully
charged, after use.
To obtain the longest possible battery life remove the battery pack
from the charger once it is fully charged.
For battery pack storage longer than 30 days: Store the battery
pack where the temperature is below 27°C and away from moisture
Store the battery packs in a 30% - 50% charged condition Every six
months of storage, charge the pack as normal.
No metal parts must be allowed to enter the battery section of the
charger (short circuit risk).
BATTERY PACK PROTECTION
In extremely high torque, binding, stalling and short circuit
situations that cause high current draw, the tool will stop for about
2 seconds and then the tool will turn OFF.
TRANSPORTING LITHIUM BATTERIES
Lithium-ion batteries are subject to the Dangerous Goods Legisla-
tion requirements.
Transportation of those batteries has to be done in accordance with
local, national and international provisions and regulations.
The user can transport the batteries by road without further
requirements.
MILWAUKEE
OREGON
4932464873
90PX056G
4931469379
MLEA041
Commercial transport of Lithium-Ion batteries by third parties is
subject to Dangerous Goods regulations. Transport preparation and
transport are exclusively to be carried out by appropriately trained
persons and the process has to be accompanied by corresponding
experts.
When transporting batteries:
Ensure that battery contact terminals are protected and insulated
to prevent short circuit. Ensure that battery pack is secured against
movement within packaging. Do not transport batteries that are
cracked or leak. Check with forwarding company for further advice
EC DECLARATION OF CONFORMITY
We declare under our sole responsibility that the product described
under "Technical Data" ful lls all the relevant provisions of the
directives
2011/65/EU (RoHS)
2006/42/EC
2014/30/EU
and the following harmonized standards have been used.
EN 60745-1:2009/A11:2010
EN 60745-2-13:2009/A1:2010
EN 55014-1:2017
EN 55014-2:2015
EN IEC 63000:2018
Measured sound power level: 97,69 dB(A)
Guaranteed sound power level: 100 dB(A)
Conformity assessment procedure according 2000/14/EC amended
by 2005/88/EC to Annex V.
Winnenden, 2019-05-24
Alexander Krug / Managing Director
Authorized to compile the technical le
Techtronic Industries GmbH
Max-Eyth-Straße 10, 71364 Winnenden, Germany
GB
English
25