TRoUBleShooTiNG

PRoBleM
Problem a: Little or no material flow
Problem B: Material leaking
Problem c: Spray pattern too thick,
runs and sags
Problem D: Spray jet pulsates
Problem E: Too much overspray
Problem F: Pattern is very light and
splotchy
i
*only thin the material as a last resort to improve spray performance.
optimal spray performance should be acheived simply by adjusting the
various controls on the unit.
this unit contains no servicable electrical parts. do not attempt to
service yourself. Store indoors with the cord wrapped around the
turbine handle.
have you tried the recommendations above and are still having
problems?
In the united States, to speak to a customer service
representative, call our technical Service at 1-800-328-8251. See www.
wagnerspraytech.com in the "Contact us" section for technical Service
hours.
CAUSe
1. Nozzle clogged.
2. Suction tube clogged.
3. air vent on suction tube blocked.
4. material flow setting too low.
5. Suction tube loose.
6. No pressure build up in container.
7. air valve tube not functioning.
8. Nozzle seal missing.
9. air filter clogged.
10. Spray material too thick.
1. Nozzle loose.
2. Nozzle worn.
3. Nozzle seal missing or worn.
4. material build-up on air cap and nozzle
1. material flow setting too high.
2. air power setting too low.
3. applying too much material.
4. Nozzle clogged.
5. air filter clogged.
6. too little pressure build-up in container.
7. Spray material too thick.
1. material in container running out.
2. air filter clogged.
3. air valve tube disconnected.
1. gun too far from spray object.
2. air power setting too high.
1. moving the spray gun too fast.
2. material flow setting too low.
3. air power setting too high.
eN
SolUTioN
1. Clean.
2. Clean.
3. Clean (see page 13)
4. Increase material flow setting.
5. remove and replace as tightly as possible.
6. tighten container.
7. make sure both ends of the tube are
connected and the valve seal is in place.
8. replace nozzle.
9. Change
10. thin*.
1. tighten.
2. replace.
3. replace nozzle.
4. Clean.
1. decrease material flow setting.
2. Increase air power setting.
3. adjust material flow or increase
movement of spray gun.
4. Clean.
5. Change.
6. tighten container.
7. thin*.
1. refill.
2. Change.
3. reconnect both ends of the air tube.
1. reduce distance (6"-8" is ideal).
2. decrease air power setting.
1. adjust material flow or decrease
movement of spray gun.
2. Increase material flow setting.
3. decrease air power setting.