2.4. Acoustic contamination
The unit produces a slight buzz when in operation. Do not place it in an occupied room, or on light supports which
might amplify this buzz. The mounting surface must be firm and appropriate for the weight of the unit.
2.5. Electrical diagram of the system
i
i
i.
Photovoltaic input.
ii.
Combiner box (optional).
iii.
Inverter.
2.6. Grid configurations
These units may be configured to work with different grid configurations. It must be configured through the display.
The different possibilities are listed below.
208 V Delta Corner Ground
208 V
In the event of using a 208 V Delta
Corner Ground or 240 V Delta Corner
Ground configuration, connect the
neutral to a grounded point in the grid.
12
ii
240 V Delta Corner Ground
N
F
240 V Split-Phase
MPP1
iv
MPP2
iii
iv.
Filter.
v.
AC output for connection to the grid.
240 V
120 V
120 V
ABE2013IQM01_ - Installation and Operation Manual
Unit description
L
v
N
N
F
N N
F
USA