„ Heating performance
Since this air conditioner utilizes outside air for heating,
z
its heating performance deteriorates as outside
temperature decreases.
(Due to heat pump system)
→In that case, use another heating appliance.
„ Defrosting
This appliance may start defrosting operation to melt
z
frost formed in the outdoor unit.
D efrosting starts
: The indoor unit fan stops (or the
speed becomes extremely slow).
→"
" (STANDBY) appears.
H eating operation resumes after several
minutes
: The indoor unit fan remains stopped (or
it will run at a very slow speed) until the indoor heat
exchanger coil warms up sufficiently.
→ " " (STANDBY) is shown.
 Defrosting is complete
operation.
→ "
" (STANDBY) disappears.
Tips for Energy Saving
„ Avoid
Do not block the air intake and outlet of the unit. (If either is obstructed, the unit will not function well, causing
z
malfunction.)
During cooling operation, use sunshades, blinds or curtains to prevent direct sunlight from entering the room.
z
„ Do
Always keep the air filter clean. (A clogged filter will impair the performance of the unit.) → "Maintenance" (P.6)
z
To prevent conditioned air from escaping, keep windows, doors and any other openings closed.
z
Important Information Regarding The Refrigerant Used
This product contains fluorinated greenhouse gases. Do not vent gases into the atmosphere.
Refrigerant type: R410A
GWP
(1)
value: 2088
(1)
GWP = global warming potential
Periodical inspections for refrigerant leaks may be required depending on European or local legislation. Please contact your local
dealer for more information.

Operation Mechanism

: The indoor unit fan starts
„ ''DRY'' operation
Once the room temperature reaches the level that was
z
set, the outdoor unit repeats the cycle of turning on and
off automatically.
When the room temperature is more likely to reach the
z
level that was set, the fan speed is set to ''breeze'' (light
wind) automatically.
(To prevent the humidity in the room from rising again)
„ Should the power failure occurs while the
unit is running
When the unit automatically resumes operation after
temporary power failure, it uses the same settings before
the power was cut off.