Installation
10 Adjust the Faucet's Water Temperature
This valve is NOT factory preset. Upon installation, the temperature of this
valve must be checked and adjusted to ensure delivery of a safe water
temperature. Water in excess of 110°F (43°C) may cause scalding.
Loosen Cap Screw about 1/4" (4-6 turns)
A
and lift up cover (do not remove).
Using cover, turn cartridge gently until
B
desired water temperature is reached. Do
not turn past stops as this may damage
unit. Push cover down and tighten screw.

11 Dryer Activation

The dryer cavity is illuminated
in white light during stand-
by mode and amber colored
during active mode.
To aid in cleaning, the dryer can be deactivated for 30
seconds. To deactivate the dryer, hold your hand beneath
the upper dryer hood at this location for three seconds. The
light will blink when the dryer is deactivated and will blink
again (after 30 seconds) when the dryer is reactivated.
Bradley • 215-1773 Rev. D; ECN 13-08-028
C
H
AV30 is shown. AV90 is similar.
Move hands forward
and backward.
slowly
lentement
lentamente
langsam
Test dryer activation by placing
A
hands into dryer cavity, moving
hands forward and backwards.
1/21/2014