Connection With The Mains; Operation; Cleaning And Maintenance - EuroLite 40000450 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Before rigging make sure that the installation area can hold a minimum point load of 10 times the device's
weight.
The device must be installed in an absolutely horizontal position.
Always install the device via all fixation holes.
Do only use appropriate screws and make sure that the screws are properly connected with the ground.
Before taking into operation for the first time, the installation has to be approved by an expert!

Connection with the mains

The electric connection must only be carried out by a qualified electrician!
In order to connect the device to the mains, you have to install a power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
Connect the device to the mains with the power-plug.
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.

OPERATION

After you connected the effect to the mains, the LED Outdoor Spot starts running.

CLEANING AND MAINTENANCE

The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
DANGER TO LIFE!
DANGER TO LIFE!
International