INSTALLATION INSTRUCTIONS
Connecting Electric Dryers (cont.)
USA only
WARNING
fire or death.
Four-wire connection for electric dryers:
Power cord
manufactured home installations, as well as all new
construction after January 1, 1996.
1. Remove the terminal block access cover on the upper
back of the dryer. Install a UL-listed strain relief into
the power cord through-hole; then thread a UL-listed,
conductor power cord through the strain relief.
UL-Listed
4-Wire Power
Cord
Terminal
UL-Listed
Strain Relief
forked terminals with upturned ends.
green ground screw to the center screw of the
terminal block. Attach the two hot leads of the power
cord to the outer terminal block screws. Attach the
white neutral wire to the center terminal block screw.
Attach the power cord ground wire to the green
ground screw.
Reinstall the terminal block access cover.
Neutral
Hot
(White)
Ground
Screw
Power Cord
Ground Wire
conductor and closed loop or
Hot
(Red)
White Wire
moved from
Ground Screw
.