Descargar Imprimir esta página

Italiana Camini POINT PLUS Instalación Uso Y Mantenimiento página 25

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 62
• ELECTRONIC EQUIPMENT
ow
sensor
SAFETY DEVICES
• THERMOCOUPLE:
Placed at the smoke outlet to detect the temperature.
Turns the stove on and off and controls its operation based on
de ned parameters.
• PRESSURE SWITCH
Positioned in the fume-aspiration area, it is triggered in the
case of a depression in the fumes circuit (e.g. obstructed ue)
and interrupts the movement of the pellets.
It blocks pellet loading causing the stove to go out.
• SAFETY THERMOSTAT:
Trips when the temperature inside the stove is too high. It
stops pellet loading, causing the stove to go out.
• AIR FLOW SENSOR
located in the suction channel, it is activated when the
combustion air
ow is not correct, with consequent pressure
problems in the smoke circuit causing the stove to shut-down.
CHARACTERISTICS
socket
RS323
Lithium
CR2032 ba-
ckup battery
Smoke-expulsion motor
screw
- 25
smoke rpm
230 vac power
supply
50hz +/-10%
internal forced-intake
ingnition element
ductwork
forced
ventilation
rear intake
ductwork
internal ducted
ducted return
ventilation
ventilation
SERIAL PORT
The Dealer can install an optional on the AUX outlet for control-
ling the process of switching on and off (e.g. telephone remote,
local thermostat), located at the rear of the stove. This can be
connected via special optional trestle (code 640560).
BACKUP BATTERY
A backup battery is found on the control board (3-Volt CR 2032
battery). Its malfunction is indicated with the following messa-
ges (not considered a defect but due to normal wear-and-tear):
"Battery check". For more detailed information, please contact
the DEALER who performed the rst 1st ignition.
FUSE *
Two fuses are inserted in the socket with switch, located on the
back of the stove, one of which operational * and the other is
held in reserve **.
-
**
*