Type A Installation Instructions
WOBBLE:
NOTE: ceiling fans tend to move during operation due to the fact that they are mounted on a rubber grommet.
If the fan was mounted rigidly to the ceiling it would cause excessive vibration. Movement of a few centimetres
is quite acceptable and DOES NOT suggest any problem.
TO REDUCE THE FAN WOBBLE: Please check that all screws which fix the mounting bracket and down rod
are secure.
BALANCING KIT: A balancing kit is provided to balance the ceiling fan on initial installation. Please refer to
the instruction in the balancing kit bag on how to use the balancing kit. The balancing kit can be used to assist
re-balancing should the ceiling fan become un-balanced again. Store your balancing kit away after installation
for future use if required.
NOISE:
When it is quiet (especially at night) you may hear occasional small noises. Slight power fluctuations and
frequency signals superimposed in the electricity for off-peak hot water control, may cause a change in fan
motor noise. This is normal. Please allow a 24-hour "breaking-in" period, most noises associated with a new
fan disappear during this time. All electric motors are audible to some extent. Please note that this is not a
product fault, and as such is not covered under warranty.
CARE AND CLEANING:
Periodic cleaning of your ceiling fan is the only maintenance required. Use a soft brush or lint free cloth
to avoid scratching the paint finish. Please turn off electricity power when you do so.
Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the
possibility of an electrical shock.
The motor has a permanently lubricated ball bearing so there is no need to oil.
NOTE: Always turn OFF the power at the mains switch before attempting to clean your fan.
Fan Size
Speed
Etra-High
60"
Medium High
Low
These are approximate measurements. They do not include data for any lamps or fixtures attached to the
ceiling fan.
2 year warranty covers the entire fan. Please refer to warranty card for the details.
9 | P a g e
AFTER INSTALLATION
TECHNICAL INFORMATION
Volts
Amps
Watts
(V)
(A)
(W)
120
0.43
30.87W
120
0.21
15.19W
120
0.05
2.14W
WARRANTY
RPM
CFM
CFM/
W
212
7738.33
250.67
156
5751.74
378.65
50
1655.43
773.56
N.W.
G.W.
C.F.
(lbs)
(lbs)
15.7
19.7
2.5
15.7
19.7
2.5
15.7
19.7
2.5