Safety Notes; Installation Instructions; Technical Data; Symbol Description - Hansgrohe Metropol S 14063000 Modo De Empleo/Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms.
• If the instantaneous water heater causes problems or
if you wish to increase the water flow, the EcoSmart
(flow limiter) located behind the aerator can be
removed.

Technical Data

This mixer series-produced with EcoSmart
limiter)
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
• The product is exclusively designed for drinking water!
• Hansgrohe mixers can be used together with hydrauli-
cally and thermically controlled continuous flow heat-
ers if the flow pressure is at least 0,15 MPa.
4
English
®
(flow
®
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min
Assembly see page 31

Symbol description

Do not use silicone containing acetic acid!
Dimensions (see page 35)

Flow diagram

(see page 36)
with EcoSmart
without EcoSmart
Operation (see page 37)
Hansgrohe recommends not to use as drink-
ing water the first half liter of water drawn
in the morning or after a prolonged period
of non-use.
Spare parts (see page 38)
Special accessories (order as an
extra)
special tool # 58085000
Installation putty
Test certificate (see page 40)
Cleaning (see enclosed brochure)
®
®

Publicidad

Tabla de contenido
loading

Tabla de contenido