Installation location requirements
Instructions for the proper installation, operation, and maintenance of the dryer may be provided as separate manu-
als or combined as one manual. Each manual provided shall contain instructions to retain the manual for future
reference.
The installation instructions for appliances that are exhausted to the outdoors shall include the following boxed
warning:
WArNiNg
w
Read all installation instructions completely before installing and operating your dryer! It is important that
you review this entire manual before installing and using your dryer. Detailed instructions concerning electrical
connections, gas connections, and exhaust requirements are provided on the following pages.
• A location that allows for proper exhaust installation.
A gas dryer must be exhausted to the outdoors. See
Venting the dryer.
• A grounded electrical outlet located within 2 ft.
(61 cm) of either side of the dryer. See Connecting
electric dryers.
Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off
at the end of an automatic cycle. This can result in longer drying times. The dryer must not be installed or stored in
an area where it will be exposed to water and/or weather. Check code requirements. Some codes limit, or do not
permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building
inspector.
NOTE
• The floor must be level, with a maximum slope of 1 inch (2.5 cm) under the entire dryer. Clothes may not tumble
properly, and automatic sensor cycles may not operate correctly if the dryer is not level.
• For a garage installation, you will need to place the dryer at least 18 inches (46 cm) above the floor. If using a
pedestal, you will need 18 inches (46 cm) to the bottom of the dryer.
Clearances
14" max.*
14" max.*
(35.6 cm)
(35.6 cm)
18" min.*
18" min.*
(45.7 cm)
(45.7 cm)
1"*
1"*
30"
30"
5"**
5"**
(2.5 cm)
(2.5 cm)
(76.1 cm)
(76.1 cm)
(12.7 cm)
(12.7 cm)
(2.5 cm)
(2.5 cm)
*Required spacing
** For side or bottom venting, 2
14" max.*
14" max.*
(35,6 cm)
(35,6 cm)
18" min.*
18" min.*
InstallatIon spacIng for recessed area or closet InstallatIon
(45,7 cm)
(45,7 cm)
The following spacing dimensions are recommended for this dryer. Although this dryer has been tested for
spacing of 1 inch (2.5 cm) clearance on the sides and rear, the recommended spacing should be considered for the
following reasons:
• Additional spacing should be considered for ease of
1"*
1"*
30"
30"
5"**
5"**
installation and servicing.
(2,5 cm)
(2,5 cm)
(76,1 cm)
(76,1 cm)
(12,7 cm)
(12,7 cm)
• Additional clearances might be required for wall, door
and floor moldings.
14" max.*
14" max.*
(35,6 cm)
(35,6 cm)
18" min.*
18" min.*
(45,7 cm)
(45,7 cm)
NOTE
There should be at least a little space around the dryer (or any other appliance) to eliminate the transfer of
1"*
1"*
30"
30"
5"**
5"**
vibration from one appliance to another. With enough vibration, the appliances will make noise or touch each
(2,5 cm)
(2,5 cm)
(76,1 cm)
(76,1 cm)
(12,7 cm)
(12,7 cm)
(2,5 cm)
(2,5 cm)
other, causing paint damage and making even more noise.
14" max.*
14" max.*
(35.6 cm)
(35.6 cm)
48 in.
48 in.
2*
2*
18" min.*
18" min.*
(310 cm
(310 cm
)
)
2
2
(45.7 cm)
(45.7 cm)
24 in.
24 in.
2*
2*
(155 cm
(155 cm
)
)
2
2
1"*
30"
30"
5"**
5"**
(76.1 cm)
(76.1 cm)
(12.7 cm)
(12.7 cm)
14" max.*
14" max.*
inches (5.1 cm) spacing is allowed.
48 in.
48 in.
2*
2*
(35,6 cm)
(35,6 cm)
(310 cm
(310 cm
)
)
2
2
18" min.*
18" min.*
(45,7 cm)
(45,7 cm)
24 in.
24 in.
2*
2*
(155 cm
(155 cm
)
)
2
2
1"*
5"**
5"**
30"
30"
(2,5 cm)
(2,5 cm)
(12,7 cm)
(12,7 cm)
deventilación de
deventilación de
(76,1 cm)
(76,1 cm)
lapuerta del armario
lapuerta del armario
14" max.*
14" max.*
(35,6 cm)
(35,6 cm)
48 in.
48 in.
2*
2*
(310 cm
(310 cm
)
)
18" min.*
18" min.*
2
2
(45,7 cm)
(45,7 cm)
24 in.
24 in.
2*
2*
(155 cm
(155 cm
)
)
2
2
1"*
30"
30"
5"**
5"**
(76,1 cm)
(76,1 cm)
(12,7 cm)
(12,7 cm)
iNSTALLATiON iNSTruCTiONS
• A sturdy floor to support the total dryer weight of 200
lbs (90.7 kg). The combined weight of a companion
appliance should also be considered.
• No other fuel-burning appliance can be installed in the
same closet as a dryer.
3"
3"
*
*
(7.6 cm)
(7.6 cm)
3"
3"
*
*
(7.6 cm)
(7.6 cm)
1"
1"
27"
27"
(2.5 cm)
(2.5 cm)
(68.6 cm)
(68.6 cm)
3"
3"
*
*
(7,6 cm)
(7,6 cm)
3"
3"
*
*
(7,6 cm)
(7,6 cm)
• Additional spacing should be considered on all sides
1"
1"
27"
27"
Requisitos
Requisitos
(2,5 cm)
(2,5 cm)
(68,6 cm)
(68,6 cm)
of the dryer to reduce noise transfer.
• For closet installation, with a door, minimum
ventilation openings in the top and bottom of the
3"
3"
*
*
door are required. Louvered doors with equivalent
(7,6 cm)
(7,6 cm)
ventilation openings are acceptable.
• Companion appliance spacing should also be
considered.
3"
3"
*
*
(7,6 cm)
(7,6 cm)
1"
1"
27"
27"
(2,5 cm)
(2,5 cm)
(68,6 cm)
(68,6 cm)
0"
0"
(0 cm)
(0 cm)
39"
39"
(99.1 cm)
(99.1 cm)
1"
1"
27"
27"
(2.5 cm)
(2.5 cm)
(68.6 cm)
(68.6 cm)
1"
1"
(2.5 cm)
(2.5 cm)
0"
0"
(0 cm)
(0 cm)
39" min.
39" min.
(99,1 cm)
(99,1 cm)
1"
1"
27"
27"
(2,5 cm)
(2,5 cm)
(68,6 cm)
(68,6 cm)
1"
1"
(2,5 cm)
(2,5 cm)
0"
0"
(0 cm)
(0 cm)
39"
39"
(99,1 cm)
(99,1 cm)
1"
1"
27"
27"
(2,5 cm)
(2,5 cm)
(68,6 cm)
(68,6 cm)
1"
1"
(2,5 cm)
(2,5 cm)
13
1"
1"
(2.5 cm)
(2.5 cm)
1"
1"
(2,5 cm)
(2,5 cm)
1"
1"
(2,5 cm)
(2,5 cm)