5. Technical data

Royal
Mains supply:
Power rating:
Delivery rate max.
Delivery height max.
Delivery pressure max.
Suction height max.
Delivery and intake connection:
Water temperature max.
Sound pressure level:
Sound power level:
With intake set
Art.-No.:

6. Electrical connections

Connect the power cable to a 230 V 50 Hz
earthed, 10 amp fuse minimum.
The appliance is switched on and off using the
integrated ON/OFF switch.
The motor is protected against overloading or
blocking by an integrated thermostat. In the event
of overheating, the thermostat switches off the
pump automatically. The pump will start up again
automatically after it has cooled down.
7. Intake line
Screw the short threaded side of the supplied
threaded nipple into the intake connection.
Screw the intake hose with the threaded nut onto
the threaded nipple by hand.
Screw the supplied intake valve by hand onto the
intake hose. If the supplied intake valve cannot be
used, a check valve should be installed in the
intake line.
The intake hose should rise from the water pick-
up point to the pump. Always avoid laying the
intake line higher than the pump. Air bubbles in
the intake line delay and hinder suction.
The intake and pressure lines must be attached in
such a way that they do not place the pump under
any mechanical strain.
The intake valve should be so far immersed in the
water that the pump cannot run dry even if the
water level falls.
If the intake line is not air-tight, the intake of air
will hinder the intake of water.
24.10.2001 11:10 Uhr
GP Jet 1202 NIRO
230V ~ 50 Hz
1200 W
4000 l/h
45 m
4,5 bar
8 m
1" IG
35°C
69 dB(A)
79,6 dB(A)
no
41.813.20
Seite 7
Avoid drawing in foreign bodies (sand etc.).
If necessary, install a prefilter for this purpose.
1
Pressure line
connection
Intake line
connection
8. Pressure line connection
The pressure line (should be at least 3/4") must
be connected to the pump's pressure line
connection (1" IG) either directly or via a threaded
nipple.
A 1/2" pressure hose can also be used with the
appropriate screw connections, of course, but this
will reduce the delivery rate.
All shut-off devices (spray nozzles, valves etc.) in
the pressure line must be fully opened when
priming so that any air in the intake line can
escape.