- To unlock, insert the key into the lock and turn clockwise until
the mechanical stop.
- To re-lock, insert the key into the lock and turn it clockwise until
it stops.
MECHANICAL EMERGENCY RELEASE (OPTIONAL)
For the S800H operator, a manual mechanical emergency
release is available as an optional item.
If the gate has to be moved manually due to a power cut or fault
of the automated system, use the release key device.
The device is inserted on the gate support bracket and enables
you to release the system from both inside and outside the
premises.
Procedure for manual leaf operation:
1) Open the protective hatch (Fig.3 ref.b).
2) Insert the release key in the lock (Fig.3 ref.c) and turn it clock-
wise sense up to its stop point.
3) Pull the release lever toward you (Fig.3 ref.a).
4) Move the leaf by hand.
Procedure for restoring the system to normal operation (Gate
released):
1) Move the release lever back to its rest position (Fig.2)
2) Insert the release key in the lock, turn it in the opposite direction
up to the stop point.
3) Move the leaf manually until the lock hooks on the shut-down
bracket.
4) Close the protective plug of the lock.
RELEASE KEY
Fig.1A
RELEASE LEVER
Every 6 months, arrange for a qualified technician to run a
functional check of the system, with special attention to the
efficiency of the safety and release devices, and to perfect
operation of the gate hinges.
Also arrange a check of the quantity of oil inside the tank - for
any topping up, strictly use OLIO FAAC HP OIL only.
SUPPORT BRACKET
RELEASE LEVER
PROTECTIVE
c
RELEASE KEY
MAINTENANCE
Fig.2
a
b
HATCH
Fig.3