Troubleshooting; Spare Parts - Franke AQUAMIX-S DN 15 Instrucciones De Montaje Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19

19. Troubleshooting

Fault
Water does not flow
Water flows continu-
ously
Water volume too low
Water too hot
Water too cold
If you cannot rectify a fault or if it is not in the list, please contact our customer
service department.

20. Spare parts

Description
1 Pressure cap. . . . . . . . . . . . . . . . . 2000105624
2 Spare parts kit:
Temperature stop
Threaded ring
Ball bearing . . . . . . . . . . . . . . . 2000104913
3 Functional element . . . . . . . . . . . . 2000104357
4 Aerator . . . . . . . . . . . . . . . . . . . . . 2000109130
5 Guide socket complete . . . . . . . . . 2030023924
6 Filters (VPE 10x). . . . . . . . . . . . . . 2000104702
10
Cause
– Water supply closed
– Functional element faulty
– Functional element faulty
– Aerator calcified
– Supply pressure too low
– Dirty filters/non-return valves
– Water supply not fully open
– Temperature limit set incorrectly or
not set
– Cold water supply cut off
– Filter/non-return valve in cold-water
connection faulty
– Temperature limit set incorrectly or
not set
– Filter/non-return valve in hot-water
connection faulty
– Hot water flow blocked
Order No.
Remedy
➯ Restore it
➯ Replace it
➯ Replace it
➯ Clean it
➯ Check it
➯ Clean it
➯ Open it
➯ Set it
➯ Open it
➯ Replace it
➯ Set it
➯ Replace it
➯ Open it

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

7612982187605

Tabla de contenido