Franke AQUAMIX-S DN 15 Instrucciones De Montaje Y Uso página 7

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
13.9 Remove the temperature stop ring (f).
13.10 Turn the tappets (g) of the temperature stop ring (f) to the horizontal position and
insert them.
Important!
Take note of the installation of the complete ball bearing.
13.11 Insert the complete ball bearing (c).
13.12 Tighten the housing nut (d), using a face spanner.
13.13 Insert the spring (e).
Important!
When putting the pressure cap in place, ensure that the tappet engages with the
corresponding groove of the temperature stop ring.
13.14 Position the pressure cap (b).
13.15 Open the water supply.
13.16 Set the desired temperature.
Turning in a clockwise direction increases the temperature of the mixed water.
Turning anti-clockwise reduces the temperature of the mixed water.
13.17 Close the water supply.
13.18 Remove the pressure cap (b) in the position in which it has been adjusted.
13.19 Remove the spring, the housing nut and the complete ball bearing (see
13.8).
13.20 Remove the temperature stop ring (f).
13.21 Engage the side of the tappet (i) with the left side of the limit stop (h).
Important!
Take note of the installation of the complete ball bearing.
13.22 Insert the complete ball bearing (c).
13.23 Tighten the housing nut (d), using a face spanner.
13.24 Insert the spring (e).
Important!
When putting the pressure cap in place, ensure that the tappet engages with the
corresponding groove.
13.25 Position the pressure cap.
13.26 Secure the pressure cap (b) on the fitting, using the grub screw (a).
step 13.6
to
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

7612982187605

Tabla de contenido