Connecting electric dryers (cont.)
USA only
WARNING
Four-wire connection for electric dryers: Direct wire
Remove 5 inches of insulation from the ground wire. Cut off
ends of the three shorter wires into a hook shape.
the dryer. Install a UL-listed strain relief into the power cord
through the strain relief.
UL-Listed
4-Wire Power
Cord
Ground Wire
5"
Terminal
UL-Listed
Strain Relief
INSTALLATION INSTRUCTIONS
cable.
reinstallation of the dryer.
3. Transfer the dryer's ground wire from behind the green ground
screw to the center screw of the terminal block. Attach the two
hot leads of the power cable to the outer terminal block screws.
Attach the white neutral wire to the center terminal block
screw. Attach the power cable ground wire to the green ground
screw.
block access cover.
Hot
Ground
Screw
Power Cord
Ground Wire
25
conductor
. Reinstall the terminal
Neutral
(White)
Hot
(Red)
White Wire
moved from
Ground Screw