Air supply
• Leister blowers must be used for the air supply (pay attention to the direction of rotation and the electrical
connection).
• For use in a dusty environment the tool should be fitted with a Leister stainless steel filter on the air intake
connection. Where a particularly critical dust problem exists (eg metal, electrically charged or damp dust) special
filters must be used to avoid short circuiting the tool.
• The hot air tool should only be supplied with air up to a max. 50ºC.
• The minimum air flow must be observed (technical data, page 11).
Operation
• Connect tool to the mains.
• The power supply cord should have the corresponding cross section area of conductor and should be fitted
by a specialist.
• As required, push-fit appropriate nozzle or reflector.
• LE 700
– Adjust the hot air temperature via the Potentiometer (5).
– As required, reduce the air flow with the regulating screw (3).
• LE 3000, 3300
– Adjust the hot air temperature via the potentiometer (5).
– As required, reduce the air flow with the air regulating knob (4).
• LE 5000, 10000 S
– Adjust the hot air temperature via the potentiometer (5).
• Make sure that the hot air can flow freely (fire hazard).
• The Leister Company, as well as the authorized Sales and Service Centres, offer advice and an introduction
to the areas of application of hot air tools, free of charge.
• After use, allow the tool to cool down by letting cold air flow through it (preventing warm air back pressure).
CAUTION:
• The mains connection should have a suitable double pole isolator with a 3 mm distance between contacts.
Accessories
• Only Leister accessories should be used.
• Accessories at www.leister.com
Let the tool cool down before changing the nozzle or reflector.
• Temperature control by additional Leister cascade controller (should only be fitted and adjusted by the Leister
Company).
Официальные поставки www.mikst.ru
Attention: always operate device with air supply !
13