To test the PIR sensor, set the light sensitivity to OFF and the
•
movement sensitivity and 5" to ON. The load should switch on
immediately and – when no movement is detected – switch off after
5s.
Note: DO NOT change the DIP switch settings when power is
connected!
Technical Specification
5.
detection angle
detection range
rated load
input
output
power supply
working temperature ‐10°C~+40°C
working humidity
time‐delay switch
light control
dimensions
weight
Use this device with original accessories only. Velleman nv cannot be
held responsible in the event of damage or injury resulted from
(incorrect) use of this device. For more info concerning this product
and the latest version of this user manual, please visit our website
www.velleman.eu. The information in this manual is subject to
change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights
reserved.
No part of this manual or may be copied, reproduced, translated or reduced
to any electronic medium or otherwise without the prior written consent of
the copyright holder.
19.09.2011
PIR416
100°
8m (@22°C)
30W resistive load
12Vdc, 2.6A
max. 12Vdc 2.5A / 30W
180~240VAC, 50~60Hz
<93%RH
5s, 30s, 1min, 3min, 5min, 8min.
< 3 Lux to 2000 Lux
visible part
hidden part (controller)
±41g
5
Ø22 x 10mm
55 x 25 x 35mm
©Velleman nv