TABLE II: GAS TECHNICAL DATA, PRESSURE, SOLID TOP BURNER NOZZLES, PILOT AND IDLE
SCREW (VALID FOR ALL GAS RANGE)
Nation
Cat.
and
Nozzle
category
ENG, ICEL, DENIM,
FIN, SWED, PORT,
2H
GREECE, IRELAND
NETHERLANDS
2L
NETHERLANDS
ICEL,
DENMARK, FIN-
3B/P
LAND, SWEDEND
NORWAY
IRELAND
PORTUGAL
ENGLAND
3+
GREECE
LUXEMBURG
R.o.A. = Regulation of primary air (1) Including the pilot thermal capacity approx. 400W.
* Pressure regulator excluded K = Short nozzle
(This unit requires a draft of at least 2cu.m/hr l kW T.C. (T.C.= Thermal Capacity).
Check kitchen aeration: it should be in compliance with law in force.
2.6.2

HOW TO ACHIEVE THE NOMINAL THERMAL CAPACITY

Check whether the unit is fitted for the gas type, pressure and category corresponding with the main gas supply.
Indication shown on packing and/or the label of the unit.
If the unit is fitted for another gas type or pressure, you need to first effect a change over to the other gas type.
See Table II for the nozzle, the idle screw (bypass), the primary air regulation, (X mm), the pilot nozzle and the nozzle pressure
for the main burner.
N.B.: The names of nozzles "2H" and "3+" are shown on the left side of Table II.
2H= G20 - 20mbar
3+= G30 29mbar and/or G31 - 37mbar coupled gas and pressure.
Table II shows the types of gas and pressure for all burners and respective nozzles, the X mm distance for the adjustment of
primary air (see Fig. 3), the idle screw (bypass), the pilot nozzle, the maximum and minimum pressure at nozzle, the maximum
and minimum thermal capacity, and the gas consumption in l/hr (15°C) or in g/hr in the case of L.P.G.
Attention: If the incoming gas' "dynamic" pressure to the unit is lower than the minimum pressure on Table II, connection
is prohibited; furthermore, the fitter should notify the gas Company that the supply pressure is too low.
N.B.: Should the pressure vary more to than +10% of the nominal pressure, e.g. for G20- 22mbar, it is advisable to mount a
pressure regulator ahead of the unit in order to guarantee the nominal pressure.
Should the supply pressure exceed the maximum pressure on Table II, e.g. for G20- 25mbar, notify the gas Company.
Make sure the inlet and nozzle pressures agrees with the values shown on Table II.
2.7

PRESSURE CHECK

INCOMING PRESSURE CHECK (Pe) Fig. 1
Pressure is measured with a manometer 0 ÷ 80mbar (precision at least 0.1mbar).
The pressure socket Fig. 1 is located on the G 1/2" gas ramp behind the panel; undo the screw (A) of the pressure socket (B),
attach the silicone rubber to the manometer, ignite the burner (Fig. 3 position 4) and take the incoming "dynamic" pressure.
Fasten the screw (A) back with a gas washer (C), check gas sealing with bubble soap.
NOZZLE PRESSURE CHECK
Type
Gas pressure
SOLID TOP
of
upstream
gas
mbar
Ø mm. Type
Nom. Min. Max.
MARKED
G20
20
17
25
G25
25
20
30
175/250K
G30*
29
25
35
G31
G30*
29
20
35
G31
37
25
45
BY-PASS
PILOT
BURNER
(22 S)
R.d.A.
Ø mm.
"targhet"
X mm.
MARKED
MARKED
170K
20
95
20
95
115K
20
65
115K
20
65
l = 15 mm
F = Fixed
- 25 -
Gas pres-
Nominal
sure at
Thermal
nozzle
kW (1)
with 25ST
Max.
Min.
100%
T.C.
mbar
mbar
Min.
27
19,2
1,5
5,5
1,55
27
23,6
1,8
5,5
1,40
19
28,8
2,4
5,5
1,55
19
28,8
2,4
5,5
1,55
36,8
3,0
Nozzle marking Ø 1/100
A = Adjustable
Gas con-
sumption
15°C
l/h
g/h
582
-
676
-
170
433
196
376
170
433
223
427
TA = Open all
GB