Operating Manual - Dehumidifier Ttk 125 S; Information About The Device - Trotec TTK 125 S Manual De Instrucciones

Ocultar thumbs Ver también para TTK 125 S:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50

Information about the device

Description of the device
This device uses the principle of condensation to
automatically dehumidify rooms.
The fan sucks damp room air through the air inlet (1),
the air filter (9), the evaporator and to the condenser
located behind it. The air is cooled at the cold evapo-
rator until it is below the dew point. Water vapour con-
tained in the room air precipitates on the evaporator
fins as either condensation or frost. The dehumidified,
cooled air is rewarmed at the condenser and blown
out at a temperature of approx. 5 °C above room tem-
perature. The drier air which is prepared in this way
mixes with the air in the room. The humidity in the
room where the device is positioned is reduced as air
constantly circulates through the device. Depending
on the air temperature and the relative humidity, the
condensed water either drops continuously or only
during the defrost phase into the condensation tray
and through the integrated drain nozzle into the con-
densation tank (4) below. The fill level of the conden-
sate tank (4) is detected by a rocker. The device has a
control panel (6) for operating and controlling the
functions. Once the maximum fill level of the conden-
sation tank (4) is reached, the condensation tank indi-
cator light ("FULL") on the control panel (6) flashes
orange. The device switches off. The condensation
tank indicator light only goes out again once the emp-
tied condensation tank (4) is reinserted. The con-
densed water can be diverted by attaching a
condensation drain hose to the hose connection (3)
(see "Operation with hose attached to the condensa-
tion plug" chapter) or by using a retrofitted condensa-
tion pump (see "Installing the condensation pump"
chapter).
The device can reduce the relative humidity of a room
by up to approx. 32 %. Because of the heat radiation
which is tied up in operation, the room temperature
can rise by approx. 1-4 °C.
GB
Device depiction
8
7
6
5
No.
Operating element
1
air inlet
2
connection for optional condensation pump
3
hose connection for condensation drain hose
4
condensation tank
5
wheels
6
control panel
7
air outlet
8
carry handle
9
air filter
Operating Manual – Dehumidifier TTK 125 S
1
2
3
4
9
B - 2

Publicidad

Tabla de contenido
loading

Tabla de contenido