Cookware recognition function
The cooking level of cooking zone can be selected by turning the knob to the according position even
if no pot is in place. The output of power starts automatically as soon as an appropriate pot is put on
the cooking zone. If no pot is being detected the display changes to the shown "pot missing" symbol
after a short time. This symbol will be shown until a appropriate pot is put on the cooking zone or the
maximum time of 10 minutes expired. The same applies if the pot is removed during normal cooking.
After 10 minutes without detected pot the cooking zone switches off automatically and can only be
activated again after returning the knob into the OFF position.
Control Lock function
The control lock is a device that protects the appliance from accidental or inappropriate use. With all
cooking zones turned off, simultaneously press and turn the first two left knobs counterwise in overwind
position "A". They need to be hold in that position for a least 2s until the symbols "L" appear on the
displays, then release the knobs.
In order to deactivate the CL function repeat the same procedure as for activating.
After unlocking all knobs have to be turned back in the zero position (if any knob was in a position
different from zero). The control is than off and can be operated as expected.
NOTE: If the knobs are not hold in the OWL position for long enough the CL will not be enabled /
displayed. If the knobs are hold in that position for more than 30 seconds the input is considered to be
invalid and a error message "Permanent use of key" will be displayed (flash symbol ).
Residual Heat indication
Cooking zones which are already switched off can still have a hot glass surface. In order to warn and
protect users from burning themselves this condition is visualized, the residual heat measurement is
done from the temperature sensor of each inductive cooking zone..
When the measured temperature drops below 60°C on the glass the symbol indicating the hot surface
disappears.