Electrical Connection - Foster 7323/945 Manual De Instalacion Y Uso

Placa inducción en vitrocerámica
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

installation

Electrical Connection

The cooktop is equipped with a flexible metal conduit encasing 3 wires ready for
connection to a grounded power supply.
1. Disconnect power.
2. Remove junction box cover if it is present.
3. Connect the flexible cable conduit from
the cooktop to the junction box using
a UL listed or CSA approved conduit
connector.
4. Tighten screws on conduit connector
if present.
5. See next page to complete installation
for your type of electrical connection.
208/240 V, 60 Hz, 16 A fuse rating
Black wire: connect to L1 (hot)
Red wire: connect to L2 (hot)
Green/Yellow wire: connect to GND
(ground)
A dedicated line and junction box should
be used to connect the cooktop to a 16
A circuit.
WARNING!
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death,
fire, or electrical shock.
UL listed or CSA
approved conduit
connector
L1 (black)
L2 (red)
GND (green/yellow)
25

Publicidad

Tabla de contenido
loading

Tabla de contenido