Technical data

Art.
Suction capacity [l/min]
Filling capacity [l/min]
Effective delivery volume at
80 % maximum pressure [l/
min]
Max. pressure [bar]
Tank size [l]
Number of air outputs
Number of cylinders
Max. speed [rpm]
Rated input power [kW]
Supply voltage [V]
Nominal current [A]
Min. fuse rating [A]
Degree of protection
Max. total length and
conductor cross-section of
extension cables
Dimensions (L × W × H)
Max. bearing/operating
temperature* [°C]
Min. bearing/operating
temperature** [°C]
Weight [kg]
Sound pressure level L
pA
Uncertainty K
[dB(A)]
pA
Sound power level L
WA
Uncertainty K
[dB(A)]
WA
Guaranteed sound power
level K
according to
WA(G)
2000/14/EC [dB(A)]
* The service life of some components (e.g. seal in
the non-return valve) is significantly reduced if the
compressor is operated at high temperatures (≥
max. bearing/operating temperature).
** At temperatures below the minimum bearing/
operating temperature there is a risk of freezing of
the condensate in the pressure tank.
0701 223 0
220
120
100
8
24
1
1
2850
1.5
230 (1~50 Hz)
6.0
10 A (slow-blow)
IP 20
3 ×1.0 mm² (10 m)
3 ×1.5 mm² (25 m)
3 ×2.5 mm² (25 m)
630 × 406 × 630
+ 40
+ 5
24
/
82 / 3
/
95 / 2
97

Symbols on the device

Symbol
Meaning
Read the operating instruc-
tions.
Warning of personal injury
due to contact with hot parts.
Wear protective glasses.
Wear hearing protection.
Warning of automatic
starting.
Warning of dangerous
electrical voltage.
Guaranteed sound power
level.
19