Device elements
Overview (Fig. I)
1 Compressor
2 Safety valve
3 Tank pressure gauge
4 Pressure tank
5 Transport handle
6 Pressure controller
7 Fastening point for system box
8 Control pressure gauge
9 Compressed air connection (quick-release con-
nector), regulated compressed air
10 ON/OFF switch
11 Air filter/air filter housing
12 Cable rewind
13 Condensate drain
14 Crane hook
15 Protective motor switch
Technical data
Art.
Suction capacity [l/min]
Filling capacity [l/min]
Effective delivery volume at
80 % maximum pressure [l/min]
Max. pressure [bar]
Tank size [l]
Number of air outputs
Number of cylinders
Max. speed [rpm]
Rated input power [kW]
Supply voltage [V]
Nominal current [A]
Min. fuse rating [A]
Degree of protection
Max. total length and conductor
cross-section of extension cables
Dimensions (L × W × H)
Max. bearing/operating
temperature* [°C]
Min. bearing/operating
temperature** [°C]
Weight [kg]
Sound pressure level L
pA
Uncertainty K
[dB(A)]
pA
20
0701 224 0
280
150
140
10
20
2
1
2850
1.7
230 (1~50 Hz)
6.5
10 A (slow-blow)
IP 20
3 ×1.0 mm² (10 m)
3 ×1.5 mm² (25 m)
3 ×2.5 mm² (25 m)
580 × 600 × 500
+ 50
0
40
/
82.5 / 1.0
Art.
Sound power level L
WA
Uncertainty K
[dB(A)]
WA
Guaranteed sound power level
K
according to 2000/14/
WA(G)
EC [dB(A)]
* The service life of some components (e.g. seal in
the non-return valve) is significantly reduced if the
compressor is operated at high temperatures (≥
max. bearing/operating temperature).
** At temperatures below the minimum bearing/
operating temperature there is a risk of freezing of
the condensate in the pressure tank.
Symbols on the device
Symbol
0701 224 0
/
95.8 / 1.0
97
Meaning
Read the operating instruc-
tions.
Warning of personal injury
due to contact with hot parts.
Wear protective glasses.
Wear hearing protection.
Warning of automatic
starting.
Warning of dangerous
electrical voltage.
Guaranteed sound power
level.