Descargar Imprimir esta página

Grohe Atrio 32 655 Manual De Instrucciones página 4

Publicidad

Idiomas disponibles

Idiomas disponibles

Application
Operation is possible in conjunction with:
- Pressurized storage heaters
- Thermally controlled instantaneous heaters
- Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters
(displacement water heaters) is not possible.
Specifications
• Max. flow
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit pressure
reducing valve
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
• Water connection
• Non reversible cartridge
Note
Major pressure differences between hot and cold
water supply should be avoided.
Installation
Flush piping system prior and after installation of
faucet thoroughly!
Mount faucet on basin
See dimensional drawing fold-out page I.
For installation, see fold-out page III,
figs. [1], [2] and [3].
Lift rod (A) must be inserted into the mixer body during
installation.
Fit swivel spout, see fig. [1].
Connect faucet
For this purpose the supply hoses must be connected
to the angle stops (or other supply points), see figs. [2]
and [3].
The hot water supply should be connected on the left,
the cold water supply on the right side.
Avoid cross connection. The cartridge is not
reversible.
1
5.7 L/min or 1.5 gpm/60 psi
7.25 psi
14.5 - 72.5 psi
145 psi
232 psi
176 °F
hot - LH
cold - RH
English
Fit pop-up drain (28 957), see fold-out page II, ensure
that flange of pop-up drain is sealed.
Open angle stops and check faucet for correct
function, see fig. [4].
Check connections for leakage.
Maintenance
Inspect and clean all parts, replace as necessary and
grease with special grease.
Shut off the hot and cold water supply!
I. Replacing the cartridge, see fold-out page III,
fig. [5].
1. Pull off cap (B).
2. Remove screw (C) and pull off lever (D).
3. Pull off cap (E).
4. Turn out screwing (F) with key 27mm.
5. Change complete cartridge (G).
Assemble in reserve order.
Observe the correct installation position!
Make sure that the cartridge seals engage in the
grooves and the locating pins at the base of the
cartridge slot into the apertures on the housing.
Screw in and tighten screwing (F).
II. Flow regulator, see fold-out page II.
Unscrew and clean flow regulator (64 196).
Assemble in reverse order.
Replacement parts, see fold-out page II ( * = special
accessories).
Care
Instructions for care of this single lever faucet will be
found in the Limited Warranty supplement.

Publicidad

loading

Este manual también es adecuado para:

Atrio 32 006