4. ELECTRONIC CONTROL UNIT
To gain access to the electronic unit and make all the regulations, unscrew the two fixing screws (Fig. 15) and open the case as shown in Fig. 16.
Fig. 15
MINI GATE 24V CONTROL UNIT
J3
L6
L5
L8
L1
L2
L3
L4
ON
1 2 3 4
P3
S1
J4
S1
START button/Programming
S2
Hand opening push button (only in programming modality)
S3
Hand closing push button (only in programming modality)
CN1
Main terminal board
J1
Motor and Encoder connector
J2
Transformer connector
J3
Garden light and limit switch connector
J4
Radio receiver connector
P1
Trimmer for anti-crushing sensibility regulation
Trimmer for motor speed regulation
P2
Trimmer for pause time regulation
P3
F1
6,3 A T motor fuse
F2
2A T accessories fuse
F3
1A T power supply fuse (3,15A T 110V version)
L1
Led start
L2
Led stop
L3
Led photocells
L4
Led safety edge
L5
Led limit switch in closing
L6
Led limit switch in opening
L7
Led encoder
L8
Led Flashing lamp
L9
Led 24V power supply
16
67410620
®
J1
L7
F1
L9
J2
P2
P1
S2
S3
CORONA
TRANSFORMER
0 V
20 V
0 V
20 V
CONNECTIONS
DIP
ON
Rev 09 - 03/2011
Fig. 16
Ground
N
F
Fig. 17
CN1
1 2 3 4 5 6 7 8 9
Automatic closing (ON) - Semiautomatic closing (OFF)
Pre-flashing (ON)
Garden light 3 min. (ON) - 1 min. (OFF)
Programming (ON)
ENGLISH
N
F
F3
10