Black Max BM10700H Serie Manual Del Operador página 18

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

USING FUEL STABILIZER
Fuel gets old, oxidizes, and breaks down over time. Adding
a fuel stabilizer (not included) extends the usable life of fuel
and helps prevent deposits from forming that can clog the
fuel system. Follow fuel stabilizer manufacturer's directions
for correct ratio of stabilizer to fuel.
 Add stabilizer to fuel tank, then fill with gasoline following
previous instructions.
NOTE: Fuel stabilizer and gasoline can be mixed prior
to filling the tank by using a gas can or other approved
fuel container and shaking gently to combine.
 Replace and secure the fuel tank cap.
 Start and run the engine for at least 5 minutes to allow
stabilizer to treat the entire fuel system.
OXYGENATED FUELS
DO NOT USE E85 FUEL. IT WILL VOID YOUR WAR-
RANTY.
NOTE: Fuel system damage or performance problems re-
sulting from the use of an oxygenated fuel containing more
than the percentages of oxygenates stated below are not
covered under warranty.
Ethanol. Gasoline containing up to 10% ethanol by volume
(commonly referred to as E10) is acceptable. E85 is not.
ELECTRIC START
This generator model is provided with both electric start and
recoil start capabilities. Avoid prolonged cranking, as it can
damage the engine.
The battery provided is a nominal 12 volt sealed recharge-
able lead-acid battery and can be operated in any position
without leakage. It complies with non-spillable battery
regulations. Its convenient size offers a 30% reduction over
conventional batteries.
NOTE: Brand new generators are shipped with the battery
connections disconnected. The positive and negative ter-
minals must be connected to the battery before the Electric
Start feature will work.
For initial battery connection, see Connecting/Disconnect-
ing Battery.
CAUTION:
On a level surface with the engine off, check the lubricant
level before each use of the generator.
OPERATION
STARTING THE ENGINE
See Figures 11 - 14.
NOTE: If location of generator is not level, the unit may not
start or may shut down during operation.
 Unplug all loads from the generator.
 Turn the fuel valve to the ON position.
 Pull the choke out to the CLOSED position.
NOTE: If engine is warm or the temperature is above
50˚F, push the choke in to the OPEN position.
 Put the engine switch in the ON ( I ) position.
 Using the switch key, turn the engine switch to "START"
or pull the recoil starting grip until the engine runs (a
maximum of 6 times).
NOTE: Do not allow the grip to snap back after starting;
return it gently to its original place.
 Allow the engine to run for 30 seconds, then move the
choke to the OPEN position.
STOPPING THE ENGINE
See Figures 12 -14.
To stop the engine under normal operating conditions:
 Remove any load from the generator.
 Turn the fuel valve to the OFF position.
 Using the switch key, put the engine switch in the
OFF ( O ) position.
To stop the engine in an emergency situation:
 Put the engine switch in the OFF ( O ) position.
WARNING:
While operating and storing, keep at least 3 feet of clear-
ance on all sides of this product, including overhead.
Allow a minimum of 30 minutes of "cool down" time be-
fore storage. Heat created by muffler and exhaust gases
may be hot enough to cause serious burns and/or ignite
combustible objects.
Page 14 — English

Publicidad

Tabla de contenido
loading

Tabla de contenido