E65
E69
E71
E73
E75
E77
8. TROUBLESHOOTING
The system fails to come on (green LED off)
Cause
» No mains voltage at the socket.
» Faulty plug or cable.
» Line fuse blown.
» Faulty on/off switch.
» Connection between wire feed carriage and
generator incorrect or faulty.
» Faulty electronics.
Cause
»
» The system has overheated (temperature alarm -
yellow LED on).
» Side cover open or faulty door switch.
» Incorrect earth connection.
» Mains voltage out of range (yellow LED on).
» Faulty electronics.
Incorrect output power
Cause
» Incorrect selection in the welding process or faulty
selector switch.
E68
E70
E72
E74
E76
E78
Solution
» Check and repair the electrical system as needed.
» Use qualified personnel only.
» Replace the faulty component.
» Contact the nearest service centre to have the system repaired.
» Replace the faulty component.
» Replace the faulty component.
» Contact the nearest service centre to have the system repaired.
» Check that the various parts of the system are properly connected.
» Contact the nearest service centre to have the system repaired.
Solution
» Replace the faulty component.
» Contact the nearest service centre to have the system repaired.
» Wait for the system to cool down without switching it off.
» In order to ensure safe operation the side cover must be closed while
welding.
» Replace the faulty component.
» Contact the nearest service centre to have the system repaired.
» Earth the system correctly.
» Read the paragraph "Installation ".
» Bring the mains voltage within the power source admissible range.
» Connect the system correctly.
» Read the paragraph "Connections ".
» Contact the nearest service centre to have the system repaired.
Solution
» Select the welding process correctly.
» Replace the faulty component.
» Contact the nearest service centre to have the system repaired.
83
TROUBLESHOOTING
EN